Screening of oxygen evolution electrocatalysts by scanning electrochemical microscopy using a shielded tip approach.

نویسندگان

  • Alessandro Minguzzi
  • Mario A Alpuche-Aviles
  • Joaquin Rodríguez López
  • Sandra Rondinini
  • Allen J Bard
چکیده

Oxygen evolution electrocatalysts in acidic media were studied by scanning electrochemical microscopy (SECM) in the substrate generation-tip collection (SG-TC) imaging mode with a 100 microm diam tip. Pure IrO2 and Sn(1-x)Ir(x)O2 combinatorial mixtures were prepared by a sol-gel route to form arrays of electrocatalyst spots. The experimental setup has been developed to optimize screening of electrocatalyst libraries under conditions where the entire array is capable of the oxygen evolution reaction (OER). The activity of individual spots was determined by reducing the interference from the reaction products of neighboring spots diffusing to the tip over the spot of interest. A gold layer deposited on the external wall of the SECM tip was used as a tip shield. In this study the shield was kept at a constant potential to reduce oxygen under mass transfer controlled conditions. The tip shield consumes oxygen coming from the neighbor spots in the array and enables the tip to correctly detect the activity of the spot below the tip. Simulations and experimental results are shown, demonstrating the effectiveness of the tip shield with the SG-TC setup in determining the properties of the composite materials and imaging arrays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methanol Tolerance of Pd–Co Oxygen Reduction Reaction Electrocatalysts Using Scanning Electrochemical Microscopy

Bimetallic Pd–Co and pure Pt electrocatalysts were evaluated for tolerance to methanol in the oxygen reduction reaction ORR in 0.5 M H2SO4 using the tip generation–substrate collection mode of scanning electrochemical microscopy. The Pd–Co electrocatalyst, Pd80Co20 80% Pd, 20% Co , showed the highest ORR activity among the different Pd–Co compositions, both in the absence and presence of MeOH. ...

متن کامل

Scanning electrochemical microscopy. 47. Imaging electrocatalytic activity for oxygen reduction in an acidic medium by the tip generation-substrate collection mode.

The oxygen reduction reaction (ORR) in acidic medium was studied on different electrode materials by scanning electrochemical microscopy (SECM) operating in a new variation of the tip generation-substrate collection mode. An ultramicroelectrode tip placed close to the substrate electrode oxidizes water to oxygen at a constant current. The substrate is held at a potential where the tip-generated...

متن کامل

Rapid Screening of Bimetallic Electrocatalysts for Oxygen Reduction in Acidic Media by Scanning Electrochemical Microscopy

Additional bimetallic electrocatalysts for the oxygen reduction reaction ORR in acidic media were designed using a previously reported thermodynamic selection guide. The electrocatalyst mixtures were prepared in large arrays on glassy carbon substrates and the electrocatalytic activity was screened using scanning electrochemical microscopy SECM . Activities were measured for a range of bimetall...

متن کامل

Characterization and theory of electrocatalysts based on scanning electrochemical microscopy screening methods.

A strategy for finding new electrocatalysts for the oxygen reduction reaction (ORR) in acidic solutions is outlined and illustrated with results for Pd-Co catalysts. This is based on establishing guidelines for selecting test systems, rapid preparation of arrays, and rapid screening by scanning electrochemical microscopy. Promising candidates are further tested as supported electrocatalysts by ...

متن کامل

Rapid Characterization of Oxygen-Evolving Electrocatalyst Spot Arrays by the Substrate Generation/Tip Collection Mode of Scanning Electrochemical Microscopy with Decreased O2 Diffusion Layer Overlap

A simple approach for the screening of oxygen evolution reaction (OER) electrocatalyst arrays by scanning electrochemical microscopy (SECM) in the substrate generation/tip collection (SG/TC) mode is described. The methodology is based on the application of a series (9−10 replicates) of double-potential steps to a catalytically active substrate electrode, which is switched between potentials whe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 80 11  شماره 

صفحات  -

تاریخ انتشار 2008