An iterative technique to segment PET lesions using a Monte Carlo based mathematical model.

نویسندگان

  • S A Nehmeh
  • H El-Zeftawy
  • C Greco
  • J Schwartz
  • Y E Erdi
  • A Kirov
  • C R Schmidtlein
  • A B Gyau
  • S M Larson
  • J L Humm
چکیده

PURPOSE The need for an accurate lesion segmentation tool in 18FDG PET is a prerequisite for the estimation of lesion response to therapy, for radionuclide dosimetry, and for the application of 18FDG PET to radiotherapy planning. In this work, the authors have developed an iterative method based on a mathematical fit deduced from Monte Carlo simulations to estimate tumor segmentation thresholds. METHODS The GATE software, a GEANT4 based Monte Carlo tool, was used to model the GE Advance PET scanner geometry. Spheres ranging between 1 and 6 cm in diameters were simulated in a 10 cm high and 11 cm in diameter cylinder. The spheres were filled with water-equivalent density and simulated in both water and lung equivalent background. The simulations were performed with an infinite, 8/1, and 4/1 target-to-background ratio (T/B). A mathematical fit describing the correlation between the lesion volume and the corresponding optimum threshold value was then deduced through analysis of the reconstructed images. An iterative method, based on this mathematical fit, was developed to determine the optimum threshold value. The effects of the lesion volume and T/B on the threshold value were investigated. This method was evaluated experimentally using the NEMA NU2-2001 IEC phantom, the ACNP cardiac phantom, a randomly deformed aluminum can, and a spheroidal shape phantom implemented artificially in the lung, liver, and brain of patient PET images. Clinically, the algorithm was evaluated in six lesions from five patients. Clinical results were compared to CT volumes. RESULTS This mathematical fit predicts an existing relationship between the PET lesion size and the percent of maximum activity concentration within the target volume (or threshold). It also showed a dependence of the threshold value on the T/B, which could be eliminated by background subtraction. In the phantom studies, the volumes of the segmented PET targets in the PET images were within 10% of the nominal ones. Clinically, the PET target volumes were also within 10% of those measured from CT images. CONCLUSIONS This iterative algorithm enabled accurately segment PET lesions, independently of their contrast value.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

RELIABILITY-BASED DESIGN OPTIMIZATION OF COMPLEX FUNCTIONS USING SELF-ADAPTIVE PARTICLE SWARM OPTIMIZATION METHOD

A Reliability-Based Design Optimization (RBDO) framework is presented that accounts for stochastic variations in structural parameters and operating conditions. The reliability index calculation is itself an iterative process, potentially employing an optimization technique to find the shortest distance from the origin to the limit-state boundary in a standard normal space. Monte Carlo simulati...

متن کامل

Perspectives for Highly-Sensitive PET-Based Medical Imaging Using βγ Coincidences

By employing the triple coincidence between the γ trajectory intersections from β decaying isotopes emitting a third, prompt, photon ( γ-PET technique), sub-millimeter spatial resolution can be reached in 3 dimensions for the localization of a point source with a reduced requirement of reconstructed intersections per voxel compared to a conventional PET reconstruction analysis. Results of a Mon...

متن کامل

Attenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study

Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...

متن کامل

A TLD based method to estimate bowtie filter shape in PET/CT

Background: In CT systems, the machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. The shape of this bowtie filter is complicated and its geometry is often not available in detail. These renders the CT dose index (CTDI) to have different values in measurement versus Monte Carlo simulation studies and other analytical calculations especially in dosimetry of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2009