Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance.

نویسندگان

  • N Al-Saadi
  • E Nagel
  • M Gross
  • A Bornstedt
  • B Schnackenburg
  • C Klein
  • W Klimek
  • H Oswald
  • E Fleck
چکیده

BACKGROUND Myocardial perfusion reserve can be noninvasively assessed with cardiovascular MR. In this study, the diagnostic accuracy of this technique for the detection of significant coronary artery stenosis was evaluated. METHODS AND RESULTS In 15 patients with single-vessel coronary artery disease and 5 patients without significant coronary artery disease, the signal intensity-time curves of the first pass of a gadolinium-DTPA bolus injected through a central vein catheter were evaluated before and after dipyridamole infusion to validate the technique. A linear fit was used to determine the upslope, and a cutoff value for the differentiation between the myocardium supplied by stenotic and nonstenotic coronary arteries was defined. The diagnostic accuracy was then examined prospectively in 34 patients with coronary artery disease and was compared with coronary angiography. A significant difference in myocardial perfusion reserve between ischemic and normal myocardial segments (1.08+/-0.23 and 2.33+/-0.41; P<0.001) was found that resulted in a cutoff value of 1.5 (mean minus 2 SD of normal segments). In the prospective analysis, sensitivity, specificity, and diagnostic accuracy for the detection of coronary artery stenosis (> or =75%) were 90%, 83%, and 87%, respectively. Interobserver and intraobserver variabilities for the linear fit were low (r=0.96 and 0.99). CONCLUSIONS MR first-pass perfusion measurements yielded a high diagnostic accuracy for the detection of coronary artery disease. Myocardial perfusion reserve can be easily and reproducibly determined by a linear fit of the upslope of the signal intensity-time curves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dobutamine induced myocardial perfusion reserve index with cardiovascular MR in patients with coronary artery disease.

Currently, adenosine or dipyridamole is commonly used for the assessment of perfusion reserve. With intolerance to these agents, dobutamine can be used alternatively or it can be used for a combined examination of wall motion and perfusion. The aim of the study was to analyze the feasibility of cardiovascular magnetic resonance (CMR) to assess perfusion reserve with dobutamine. Alterations of m...

متن کامل

Magnetic resonance imaging perfusion to assess transmural flow distribution

Cardiovascular magnetic resonance (CMR) is increasingly used to assess non-invasively the presence and the extent of myocardial ischemia. CMR perfusion has been shown to be superior to nuclear perfusion imaging, allows high-resolution quantitative assessment of myocardial perfusion reserve, has been validated against invasive reference standards and microspheres and therefore has the potential ...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Additive value of magnetic resonance coronary angiography in a comprehensive cardiac magnetic resonance stress-rest protocol for detection of functionally significant coronary artery disease: a pilot study.

BACKGROUND Cardiovascular magnetic resonance (CMR) myocardial perfusion imaging (MPI) is a state-of-the-art noninvasive modality for detection of myocardial ischemia and coronary artery disease. Magnetic resonance coronary angiography (MRCA) allows visualization of the coronary tree, but its incremental value as part of a CMR protocol including MPI and late gadolinium enhancement (LGE) is not w...

متن کامل

The impact of myocardial flow reserve on the detection of coronary artery disease by perfusion imaging methods: an NHLBI WISE study.

Myocardial flow reserve (MFR) is not routinely assessed in myocardial perfusion imaging (MPI) studies but has been hypothesized to affect test accuracy when assessing disease severity by coronary vessel lumenography. Magnetic resonance imaging (MRI) is an emerging diagnostic technique that can both perform MPI and assess MFR. We studied women (n = 184) enrolled in the Women's Ischemia Syndrome ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 101 12  شماره 

صفحات  -

تاریخ انتشار 2000