Oxygenator exhaust capnography for prediction of arterial carbon dioxide tension during hypothermic cardiopulmonary bypass.

نویسندگان

  • Anis Baraka
  • Mohamad El-Khatib
  • Eva Muallem
  • Salim Jamal
  • Sania Haroun-Bizri
  • Marie Aouad
چکیده

Continuous monitoring and control of arterial carbon dioxide tension (P(a)CO2) during cardiopulmonary bypass (CPB) is essential. A reliable, accurate, and inexpensive system is not currently available. This study was undertaken to assess whether the continuous monitoring of oxygenator exhaust carbon dioxide tension (PexCO2) can be used to reflect P(a)CO2 during CPB. A total of 33 patients undergoing CPB for cardiac surgery were included in the study. During normothermia (37 degrees C) and stable hypothermia (31 degrees C), the values of PexCO2 from the oxygenator exhaust outlet were monitored and compared simultaneously with the P(a)CO2 values. Regression and agreement analysis were performed between PexCO2 and temperature corrected-P(a)CO2 and temperature uncorrected-P(a)CO2. At normothermia, a significant correlation was obtained between PexCO2 and P(a)CO2 (r = 0.79; p < 0.05); there was also a strong agreement between PexCO2 and P(a)CO2 with a gradient of 3.4 +/- 1.9 mmHg. During stable hypothermia, a significant correlation was obtained between PexCO2 and the temperature corrected-P(a)CO2 (r = 0.78; p < 0.05); also, there was a strong agreement between PexCO2 and temperature corrected-P(a)CO2 with a gradient of 2.8 +/- 2.0 mmHg. During stable hypothermia, a significant correlation was obtained between PexCO2 and the temperature uncorrected-P(a)CO2 (r = 0.61; p < 0.05); however, there was a poor agreement between PexCO2 and the temperature uncorrected-P(a)CO2 with a gradient of 13.2 +/- 3.8 mmHg. Oxygenator exhaust capnography could be used as a mean for continuously monitoring P(a)CO2 during normothermic phase of cardiopulmonary bypass as well as the temperature-corrected P(a)CO2 during the stable hypothermic phase of CPB.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Membrane oxygenator exhaust capnography for continuously estimating arterial carbon dioxide tension during cardiopulmonary bypass.

Typically, the standard practice for measuring the arterial blood carbon dioxide tension (PaCO2) during cardiopulmonary bypass (CPB) is to take intermittent blood samples for analysis by a bench blood gas analyzer. Continuous inline blood gas monitors are available but are expensive. A potential solution is the capnograph, which was evaluated by determining how accurately the carbon dioxide ten...

متن کامل

Alpha-stat capnography for the Sorin Monolyth oxygenator.

Monitoring the carbon dioxide exhaust of an oxygenator is an inexpensive method to accurately predict and control the arterial carbon dioxide tension during cardiopulmonary bypass (CPB). The partial pressure of carbon dioxide in the exhaust ventilating gas (p exCO 2) was continuously monitored from the capnograph port of the Sorin Monolyth oxygenator during CPB. At the time of routine arteria...

متن کامل

مقایسه دی اکسیدکربن انتهای بازدمی و شریانی در بیماران کاندید پیوند عروق کرونر

Background: Measuring end tidal carbon dioxide (ETCo2) is one of the methods used for estimating arterial carbon dioxide (PaCo2) during general anesthesia. ETCo2 measurements maybe obviate the need for repeating arterial puncture for determination of arterial PaCo2. This study performed to determine the accuracy of ETCo2 levels as a measure of PaCo2 levels in patients undergoing coronary artery...

متن کامل

A comparative study between hypothermic and normothermic cardiopulmonary bypass in open heart surgery in dogs--effects on systemic hemodynamics.

Open heart surgery was performed on two groups of dogs under extracorporeal circulation with or without hypothermia to investigate hemodynamic changes during extracorporeal circulation. During hypothermic cardiopulmonary bypass (CPB), arterial O2 tension and postoperative blood pressure were favorably maintained, indicating that hypothermic extracorporeal circulation can be performed for a long...

متن کامل

Aerobic, anaerobic and combination estimates of cerebral hypoperfusion during and after cardiac surgery.

We studied 15 patients undergoing cardiac surgery involving hypothermic cardiopulmonary bypass (CPB). Cerebral arteriovenous difference in oxygen content (AVDO2) was significantly less during CPB and for up to 18 h after operation compared with pre-CPB values (P < 0.05). There were no significant changes in mean jugular bulb oxyhaemoglobin saturation (SjvO2), cerebral arteriovenous difference i...