A Filter with Three Voltage-inputs and One Voltage-output and One Current-output Using Current Conveyors
نویسندگان
چکیده
A new biquadratic filter with three voltage-inputs and one voltageoutput and one current-output is presented. The filter employs two types of current conveyors, grounded resistors and grounded capacitors to realize the lowpass, highpass and bandpass responses by selecting different input signals. The proposed circuit has high input impedance, independent adjustments of angular frequency 0 and quality factor Q using capacitors and resistors, in addition to low active and passive sensitivities. Hspice simulation results are given to demonstrate the new proposed biquadratic filter.
منابع مشابه
Triple-Input Single-Output Voltage-Mode Multifunction Filter Using Only two Current Conveyors
A new voltage-mode triple-input single-output multifunction filter using only two current conveyors is presented. The proposed filter which possesses three inputs and single-output can generate all biquadratic filtering functions at the output terminal by selecting different input signal combinations. The validity of the proposed filter is verified through PSPICE simulations. Keywords—Active Fi...
متن کاملAn LCL-filtered Single-phase Multilevel Inverter for Grid Integration of PV Systems
Integration of the PV into the electrical grid needs power electronic interface. This power electronic interface should have some key features and should come up with grid codes. One of the important criteria is the quality and harmonic contents of the current being injected to the grid. High-order harmonics of the grid current should be very limited (lower than 0.3% of the fundamental current)...
متن کاملVoltage Regulation of a Negative Output Luo Converter Using a PD-PI Type Sliding Mode Current Controller
This paper describes a new design for direct sliding mode method with a high switching frequency using the PD-PI type sliding surface applied to a negative output Luo converter worked in continuous current mode for applications required constant power source such as aerospace applications, medical equipment and etc. Because of the output power and line changes, the converter model is also nonli...
متن کاملHigh-Order CCII-Based Mixed-Mode Universal Filter
This paper presents a new high-order mixedmode (including voltage, current, transadmittance, and transimpedance modes) universal filter structure using n+1 second-generation current conveyors (CCIIs), n grounded capacitors and n+2 resistors, which are the minimum number of active component counts for realizing an nth-order mixedmode universal filtering responses (low-pass, high-pass, bandpass, ...
متن کاملMixed-Mode Biquadratic Filter Using Only Two DVCC and Grounded Passive Components
This paper presents a new mixed-mode (including voltage, current, transadmittance, and transimpedance modes) biquad filter using only two differential voltage current conveyors (DVCCs), two grounded capacitors and three grounded resistors, which are the least number of active components and the minimum number of grounded passive components necessary for realizing current-mode (with high output ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004