In Vitro and in Vivo Analysis of Squeaking Frequencies in Ceramic-on-ceramic Total Hip Prosthesis
نویسندگان
چکیده
INTRODUCTION: Squeaking after total hip replacement has been reported in up to 10% of patients (1). Some authors proposed that sound emissions from squeaking hips result from resonance of one or other or both of the metal parts and not the bearing surfaces (2). There is no reported in vitro study about the squeaking frequencies under lubricated regime. The goal of the study was to reproduce the squeaking in vitro under lubricated conditions, and to compare the in vitro frequencies to in vivo frequencies determined in a group of squeaking patients. The frequencies may help determining the responsible part of the noise. METHODS: Four patients, who underwent THR with a Ceramic-on-Ceramic THR (Trident®, Stryker®) presented a squeaking noise. The noise was recorded and analysed with acoustic software (FMaster®). In-vitro 3 alumina ceramic (Biolox Forte Ceramtec®) 32 mm diameter (Ceramconcept®) components were tested using a PROSIM® hip friction simulator. The cup was positioned with a 75° abduction angle in order to achieve edge loading conditions. The backing and the cup liner were cut with a diamond saw, in order to avoid neck-head impingement and dislocation in case of high cup abduction angles (Figure1). The head was articulated ± 10° at 1 Hz with a load of 2.5kN for a duration of 300 cycles. The motion was along the edge. Tests were conducted under lubricated conditions with 25% bovine serum without and with the addition of a 3 body alumina ceramic particle (200 μm thickness and 2 mm length). Figure 1. The back and the liner were cut in order to avoid neckhead impingement in case of high cup abduction angle. Before hand, engineering blue was used in order to analyze the contact area and to determine whether edge loading was achieved. RESULTS SECTION: Edge loading was obtained incompletely (Figure 2). In-vitro, no squeaking occurred under edge loading conditions. However, with the addition of an alumina ceramic 3 body particle in the contact region squeaking was obtained at the beginning of the tests and stopped after ~20 seconds (dominant frequency 2.6 kHz) (Figure 3-a). Figure 2. Edge loading was achieved incompletely when using a 75° cup abduction angle In-vivo, recordings had a dominant frequency ranging between 2.2 and 2.4 kHz. (Figure 3-b) Figure 3. In vitro Squeaking showed a major fundamental frequency of about 2.6 kHz and corresponding harmonics. Patients presented a dominant frequency about 2.4 kHz DISCUSSION: For the first time, squeaking was reproduced in vitro under lubricated conditions. In-vitro noises followed edge loading and 3 body particles and despite, the severe conditions, squeaking was intermittent and difficult to reproduce. However, squeaking is probably more difficult to reproduce because the cup was cut and the head was fixed in the simulator, preventing vibration to occur. Furthermore, edge loading was incompletely achieved in case of no inserted ceramic ship. No damage was observed on the components, however, the test duration was very short. Squeaking noises of a similar frequency were recorded in-vitro and invivo. The lower frequency of squeaking recorded in-vivo, demonstrates a potential damping effect of the soft tissues. Therefore, the squeaking in the patients was probably related to the bearing surfaces and modified lubrication conditions that may be due to edge loading. Varnum et al reported recently (3) that all the revised squeaking patients had a neckcup impingement with metal 3 body particles. These metallic wear particles may generate squeaking as shown in vitro. However, a larger cohort of squeaking patients is needed to confirm these results. The determined values of frequencies may help to analyze the squeaking patients in order to determine the mechanism generating the sound. REFERENCES: 1Jarret et al: The squeaking Hip: An under-reported phenomenon of ceramic-on-ceramic total hip arthroplasty. AAOS 2007, Poster 198 2Walter et al: Acoustic Analysis of Squeaking Hips ,21, AAOS 2008 3Varnum et al: Ceramic Bearings in Total Hip Arthroplasty: Frequency and Type of Noises. EFORT 9 Meeting, Nice, France 2008 θ Cup
منابع مشابه
Ceramic liner fractures presenting as squeaking after primary total hip arthroplasty.
BACKGROUND Squeaking after ceramic-on-ceramic total hip arthroplasty is a relatively uncommon phenomenon. It usually does not require treatment in the absence of pain, mechanical symptoms, and/or relentless squeaking. The purpose of this investigation was to report on four patients who presented with hip pain and squeaking due to fractured ceramic liners after ceramic-on-ceramic total hip arthr...
متن کاملAn estimation of the incidence of squeaking and revision surgery for squeaking in ceramic-on-ceramic total hip replacement: a meta-analysis and report from the Australian Orthopaedic Association National Joint Registry.
Squeaking arising from a ceramic-on-ceramic (CoC) total hip replacement (THR) may cause patient concern and in some cases causes patients to seek revision surgery. We performed a meta-analysis to determine the incidence of squeaking and the incidence of revision surgery for squeaking. A total of 43 studies including 16,828 CoC THR that reported squeaking, or revision for squeaking, were entered...
متن کاملMeta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients
PURPOSE The purpose of this study was to assess the squeaking incidence and risk factors after primary ceramic-on-ceramic total hip arthroplasty (THA) in Asian patients using meta-analysis. MATERIALS AND METHODS We performed a meta-analysis of published data on the squeaking incidence and risk factors from 2000 to 2013. Eight studies in Asians were analyzed for both squeaking incidence and ri...
متن کاملTotal Hip Arthroplasty Using Ceramic-on-ceramic Bearing Surfaces: Long-term Assessment of Squeaking Sounds
Purpose This study was performed to characterize the natural history of squeaking sounds that occur following total hip arthroplasty (THA) using ceramic-on-ceramic bearing surfaces and its potential correlation with clinical and/or radiological results. Materials and Methods This study included 47 patients who underwent THA between April 1999 and April 2005, and had at least 10 years of follo...
متن کاملMicroseparation and stripe wear in alumina-on-alumina hip implants.
The combination of materials that still has highest wear resistance for total hip replacement is ceramic-on-ceramic. However, brittleness is a major concern for ceramics: in vivo and in vitro studies on ceramic hip prostheses correlate microseparation with hip noise, ceramic wear, or ceramic liner damage. Ceramic microseparation can lead to edge load, ceramic head wear, and squeaking. The aim o...