HPLC with UV or mass spectrometric detection for quantifying endogenous uracil and dihydrouracil in human plasma.
نویسندگان
چکیده
BACKGROUND We developed and compared 2 different methods for quantifying uracil (U) and dihydrouracil (UH(2)) in BSA and human plasma. Special attention was paid to the selectivity/specificity and the absence of a matrix effect. The UH(2)/U ratio is intended as a biomarker to identify patients with deficiency in 5-fluorouracil metabolism. METHODS We quantified U and UH(2) with 2 liquid chromatography methods after solid-phase extraction, one with UV detection (LC-UV) and the other with mass spectrometric detection (LC-MS). We selected 2 internal standards to prevent the risk of interferences. Separation was achieved with a Waters Atlantis dC18 column (LC-MS) or a Waters SymmetryShield RP18 column connected with an Atlantis dC18 (LC-UV). Mass spectrometric data were acquired in single-ion monitoring mode. RESULTS Assay imprecision in BSA solution was <15% (LC-UV) and <12% (LC-MS); in plasma, assay imprecision was <9.5% and <9.0%, respectively. Recoveries were 88.2%-110% (LC-UV) and 94.8%-107% (LC-MS). Extraction efficiencies were >or=89.0%. In BSA, the lower limits of quantification for U and UH(2) were 2.5 microg/L and 6.25 microg/L, respectively, for the LC-UV method and 2.5 microg/L and 3.1 microg/L for LC-MS. The corresponding values in plasma were 11.6 microg/L and 21.5 microg/L, and 4.1 microg/L and 12.1 microg/L. CONCLUSIONS To estimate endogenous U and UH(2) concentrations and their ratio, we recommend the use of a drug-free human plasma pool in which baseline U and UH(2) concentrations have previously been measured with the standard-addition method. Our LC-MS method, which has the better test performance and is useful for measuring UH(2)/U ratios in cancer patients, is preferred when this equipment is available.
منابع مشابه
Validation of an ultra-high performance liquid chromatography tandem mass spectrometric method for quantifying uracil and 5,6-dihydrouracil in human plasma.
A simple, rapid, sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry method (Waters UPLC-MS-MS) is developed and validated for the quantification of uracil (U) and 5,6-dihydrouracil (UH2) levels in human plasma. Analytes are extracted using ethyl acetate and isopropanol after deproteination, and separated by high-performance liquid chromatography (HPLC) ...
متن کاملDevelopment and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection
A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...
متن کاملDevelopment and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection
A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...
متن کاملA simple and sensitive fully validated HPLC-UV method for the determination of 5-fluorouracil and its metabolite 5,6-dihydrofluorouracil in plasma.
The authors developed a simple and sensitive, fully validated HPLC-UV method for the determination of both 5-FU and its metabolite DHFU in small-volume plasma samples. The analytes were separated on a 4.6 x 250 mm ID Atlantis dC18 5-microm column with isocratic elution at room temperature. Chlorouracil was used as internal standard. The analytes were detected with an UV diode array detector. DH...
متن کاملLiquid chromatography-tandem mass spectrometric assay for the analysis of uracil, 5,6-dihydrouracil and beta-ureidopropionic acid in urine for the measurement of the activities of the pyrimidine catabolic enzymes.
A liquid chromatography-tandem mass spectrometric assay for the determination of uracil, 5,6-dihydrouracil and beta-ureidopropionic acid in urine was developed to measure the activities of enzymes involved in pyrimidine breakdown. The assay was required to investigate the relation between the uracil-dihydrouracil ratio and toxicities observed after treatment with fluoropyrimidines drugs. After ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 54 9 شماره
صفحات -
تاریخ انتشار 2008