Electrochemical lysis of an intraocular tumour using a combination of electrode placements

نویسندگان

  • Y Belyy
  • A Tereshchenko
  • A Shatskih
چکیده

UNLABELLED The objective of this experimental study was to develop a new combination technique for electrode placement and the histomorphological evaluation of its effectiveness for the electrochemical lysis of large intraocular tumours. MATERIALS AND METHODS The ECL was conducted on two freshly enucleated eyes containing large tumours, with maximal prominence of 11 and 12 mm and maximal base diameter of 16 and 19 mm, respectively. The ECL was carried out using an ECU-300 (Soring, Germany) apparatus generating an electrochemical charge of 30-35 K. In the course of the ECL procedure we used a new original combination technique of electrode placement, i.e., the anode was a surface electrode and the cathode was an intrastromal electrode. The anode had an original design. RESULTS A greyscale B-scan performed after the ECL completion showed decreased echogenicity and heterogeneity of the echo-structure of the tumour. According to the bioimpedancemetry data, the average duration of the ECL session was from 20 to 30 minutes depending on the tumour size. The results of pathomorphological examination performed after the ECL on two freshly enucleated eyes appeared to be similar. Thus, in both cases after lysis the eyeball did not change its size or shape. In both cases the tumour originated from the choroid plexus and showed subtotal necrosis. There was a pronounced boundary between the intact and electrochemically damaged tumour regions which attests to the local effect of the ECL restricted to the electrode placement area only. DISCUSSION The growing interest in the ECL procedure is due not only to its availability and low cost but mainly to its real clinical effect demonstrated in numerous publications. The absence of a developed ECL technology for the treatment of intraocular tumors, and, hence, reports on its clinical effectiveness, gave us the impetus to conduct this study. The proposed ECL method is promising and can be considered as optional for the organ-sparing treatment of large-sized intraocular tumours. Further optimization of the ECL parameters, as well as the development of sets of surface and intrastromal electrodes for different types of tumours, is required.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical procedure for intraocular electrochemical lysis during endoresection

Optimal clinical approaches to the treatment of large intraocular lesions located in the posterior pole of the eye remain controversial. In our opinion, the introduction of innovative techniques into the clinical practice of vitreoretinal surgery professionals as well as the implementation of new techniques designed to destroy tumour tissue will make endoresection one of the most promising alte...

متن کامل

A Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay

We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...

متن کامل

An Electrochemical Investigation of Nano Cerium Oxide/Graphene as an Electrode Material for Supercapacitors

In this paper, the effect of cationic and anionic ion sizes on the charge storage capability of graphene nanosheets is investigated. The electrochemical properties of the produced electrode are studied using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques in 3M NaCl, NaOH, and KOH electrolytes. Scanning electron microscopy (SEM) is used to characterize the mi...

متن کامل

Efficient Determination of Butylated Hydroxyanisole Using an Electrochemical Sensor Based on Cobalt Oxide Nanoparticles Modified Electrode

A simple and reliable electrochemical sensor based on cobalt oxide nanoparticles modified glassy carbon electrode (GCE/CoOxNPs) for determination of butylated hydroxyanisole is presented here. The nanoparticles were fabricated by electrodepositing method. The modified electrode shows excellent catalytic activity toward butylated hydroxyanisole oxidation in pH 12.0 phosphate buffer solution (PBS...

متن کامل

Electrochemical Sulfate Removal from Aqueous Solution Using Sandwich Panel Carbon Cloth Electrode by Steel Mesh: A laboratory study

Background and Objectives: Sulfate is one of the chemical pollutants in water that can cause adverse health effects such as digestive and blood problems at high concentrations in humans. Conversion of sulfate to substances such as hydrogen sulfide can corrode metal pipes. Therefore, the aim of this study was to investigate the effect of electrochemical sulfate removal using a sandwich panel car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012