The e2v CCD236 is a swept charge device (SCD) designed as a soft X-ray detector for spectroscopy in the range 0.8 keV to 10 keV [1]. It benefits from improvements in design over the previous generation of SCD (the e2v CCD54) [2] to allow for increased detector area, a reduction in split X-ray events and improvements to radiation hardness [3]. To enable the suppression of surface dark current the device is clocked continuously, therefore there is no positional information making responsivity variations difficult to measure. This paper describes investigated techniques to achieve a responsivity map across the device using masking and XRF, and spot illumination from an organic light-emitting diode (OLED). The results of this technique should allow a deeper understanding of the device sensitivity and allow better data interpretation in SCD applications.
منابع مشابه
The Open University ’ s repository of research publications and other research outputs Responsivity mapping techniques for the non - positional CCD : the swept charge device CCD 236
The e2v CCD236 is a swept charge device (SCD) designed as a soft X-ray detector for spectroscopy in the range 0.8 keV to 10 keV [1]. It benefits from improvements in design over the previous generation of SCD (the e2v CCD54) [2] to allow for increased detector area, a reduction in split X-ray events and improvements to radiation hardness [3]. To enable the suppression of surface dark current th...
متن کاملمقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندانهای اندو شده (مطالعه آزمایشگاهی)
Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth. Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...
متن کاملDefocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique
Defocusing effects in modulation transfer function (MTF) measurement of charge coupled device (CCD) cameras is the main focus of current paper. We introduce measuring Point-spread function (PSF) in order to calculate the MTF and further more we will study the shape of MTF and its cut-off frequency by adjusting the lens focusing in different locations. A collimated white light LED by broadband s...
متن کاملLow-uncertainty absolute radiometric calibration of a CCD
The use of CCD detectors for radiometric measurements has proven to be very interesting for a variety of fields. This work presents an experimental method for the low-uncertainty calibration of the spectral radiant exposure responsivity of a CCD detector. It contains the description of the experimental setup as well as the analysis of the various sources of uncertainty. The overall result shows...
متن کاملLow noise charge injection in the CCD22
The inclusion of a charge injection structure on a charge coupled device (CCD) allows for the mitigation of charge transfer losses caused by radiation induced charge trapping defects. Any traps present in the pixels of the CCD are filled by the injected charge as it is swept through the device improving the charge transfer efficiency in the subsequent acquired images. To date, a number of CCD t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013