Tumor SNR Analysis in Scintimammography by Dedicated High Contrast Imager

نویسندگان

  • Maria Nerina Cinti
  • Roberto Pani
  • Rosanna Pellegrini
  • Claudio Bonifazzi
  • Raffaele Scafè
  • Giuseppe De Vincentis
  • Franco Garibaldi
  • Francesco Cusanno
  • Renato Campanini
  • Nico Lanconelli
  • Alessandro Riccardi
چکیده

A new gamma camera dedicated to scintimammography (single photon emission mammography—SPEM) now has a full-breast field of view. One can clinically examine a mildly compressed breast with a cranio-caudal-like projection as one would in X-ray mammography. This camera is based on pixelated scintillation arrays and position sensitive photomultiplier tubes. By reducing the collimator-tumor distance, we enhanced the geometric spatial resolution and the contrast. Unfortunately, due to the low counting rates in scintimammography, low contrast images are usually seen, particularly with small tumors. The aim of this paper is to evaluate how a camera, based on a pixelated detector, can improve the SNR values for small tumors by effectively correcting the spatial response. The procedure is based on good pixel identification. We used a small gamma camera with a metal channel dynode position sensitive photomultiplier (Hamamatsu R7600-C8) coupled to different CsI(Tl) scintillator arrays with a general purpose collimator. This type of photomultiplier drastically reduces the charge spread and improves the intrinsic characteristics of the imager. The dimensions of the CsI (Tl) matched the photomultiplier’s active area (22 22 mm). Utilizing its very high intrinsic spatial resolution, we created a look up table to correct gain and spatial nonuniformities. We used a breast and torso phantom to characterize the SNR as a function of pixel size, thickness of the breast, tumor size, and depth. The data showed that the SNR depends principally on the match between the tumor and pixel size. For instance, for a 6 mm diameter tumor, the best SNRs were obtained by a 2 2 mm array. For larger tumors, up to 10 mm diameter, a larger pixel 3 3 mm or 4 4 mm, optimizes the SNR value. We compared the results of this camera with those from both a SPEM gamma camera and a standard Anger camera.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Breast Tumor Detectability With Two Dedicated, Compact Scintillation Cameras

As part of the development of dedicated scintillation cameras for breast imaging, we compared the performances of two dedicated cameras with a standard clinical camera (Siemens Orbiter). One dedicated camera was based on a single position-sensitive photomultiplier tube (PSPMT) coupled to a 6 cm by 6 cm by 6 mm NaI(Tl) crystal. The other (LumaGem) was based on multiple-PSPMTs coupled to a 2 mm 2...

متن کامل

Determination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging

Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...

متن کامل

Breast cancer imaging: a new role of Tc-99m sestamibi prone scintimammography for diagnosisof breast cancer

Mammography remians the procedure of choice in screening asymptomatic women for breast cancer. However, in patients with symptoms, other types of imaging play an important role in the detection of malignancies. The high cost and lack of availability of PET and MRI largely precludes the use in this patient population. TI-201 is nbt the imaging agent of choice because of its wash-out and redistri...

متن کامل

Principal component analysis of scintimammographic images.

The recent development of new gamma imagers based on scintillation array with high spatial resolution, has strongly improved the possibility of detecting sub-centimeter cancer in Scintimammography. However, Compton scattering contamination remains the main drawback since it limits the sensitivity of tumor detection. Principal component image analysis (PCA), recently introduced in scintimam nogr...

متن کامل

Evaluation of Performance of Dedicated, Compact Scintillation Cameras

As part of the development of dedicated scintillation cameras, we compared the performances of 2 dedicated cameras with a standard clinical camera (Siemens Orbiter). One dedicated camera was based on a single Position Sensitive Photomultiplier (PSPMT) coupled to a 6 cm by 6 cm by 6 mm NaI(T1) crystal and the other was based on multiplePSPMTs coupled to a 2 mm by 2 mm by 6 mm matrix of NaI(T1) c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001