Identification of coronary plaque sub-types using virtual histology intravascular ultrasound is affected by inter-observer variability and differences in plaque definitions.
نویسندگان
چکیده
BACKGROUND Recent studies show that virtual histology intravascular ultrasound (VH-IVUS) can identify plaques at high risk of rupture, such as thin-capped fibroatheromata, raising the possibility of immediate targeted intervention. However, plaque classification entails border recognition and subjective assessment of plaque architecture, introducing inter-observer variability without confirmation by core-labs. Furthermore, the accuracy of local versus core-laboratory VH-IVUS plaque classification and effects of different plaque definitions have not been examined. METHODS AND RESULTS Local observers classified 100 VH-IVUS-defined coronary plaques to determine single center inter-observer variability; multi-center variability was determined by comparison with VH-IVUS core-laboratory analysis, and compared with gray-scale IVUS. Frequency of plaque types using different published plaque definitions also was determined. Single-center VH-IVUS inter-observer agreement was strong (kappa=0.86), but lower for thin-capped fibroatheromatas (k=0.59) because of observer judgments on presence and location of confluent necrotic core. Multi-center inter-observer agreement for plaque classification was lower again (k=0.71), particularly for thin-capped fibroatheromatas (k=0.56). Different plaque definitions further reduced VH-IVUS-defined thin-capped fibroatheromata numbers by 44%. The diagnostic accuracy of gray-scale IVUS to identify thin-capped fibroatheromata was poor for both observers (21 and 29% correct), with low inter-observer agreement (k=0.14). CONCLUSIONS VH-IVUS plaque classification, and particularly VH-IVUS-defined thin-capped fibroatheromata identification, varies significantly between local observers, and particularly in comparison with core-laboratory analysis. Differences in VH-IVUS plaque definitions introduce further variability between studies. These factors reduce the use of VH-IVUS plaque classification to guide intervention in a "live" clinical setting, and also affect comparison of diagnostic accuracy and natural history of plaques between studies.
منابع مشابه
In vitro analysis of coronary atheromatous lesions by intravascular ultrasound; reproducibility and histological correlation of lesion morphology.
AIM To determine the reproducibility and histological correlation of qualitative intravascular ultrasound imaging of atheromatous coronary arteries using the recently proposed European Society of Cardiology classification of plaque composition in conditions approximating the clinical setting. METHODS Atheromatous lesions (n=21), identified from 30 post-mortem human coronary arteries, were ima...
متن کاملAtherosclerotic plaque composition and classification identified by coronary computed tomography: assessment of computed tomography-generated plaque maps compared with virtual histology intravascular ultrasound and histology.
BACKGROUND Computed tomography (CT) is used routinely for coronary angiography, and higher-risk features of plaques can also be identified. However, the ability of CT to discriminate individual plaque components and classify plaques according to accepted histological definitions is unknown. METHODS AND RESULTS We first determined CT attenuation ranges for individual plaque components using co...
متن کاملMulti-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions.
AIMS The aim of this study was to investigate the reproducibility of intravascular optical coherence tomography (IVOCT) assessments, including a comparison to intravascular ultrasound (IVUS). Intra-observer and inter-observer variabilities of IVOCT have been previously described, whereas inter-institute reliability in multiple laboratories has never been systematically studied. METHODS AND RE...
متن کاملType 2 diabetes is associated with more advanced coronary atherosclerosis on multislice computed tomography and virtual histology intravascular ultrasound.
BACKGROUND Data on coronary plaque observations on multi-slice computed tomography (MSCT) in patients with type 2 diabetes are scarce. METHODS AND RESULTS In total, 60 patients (19 with diabetes) underwent 64-slice MSCT, followed by conventional coronary angiography with intravascular ultrasound (IVUS). Non-invasively, the extent of coronary atherosclerosis and 3 plaque types (non-calcified, ...
متن کاملEarly Effects of Intensive Lipid-Lowering Treatment on Plaque Characteristics Assessed by Virtual Histology Intravascular Ultrasound
PURPOSE The effects of short-term intensive lipid-lowering treatment on coronary plaque composition have not yet been sufficiently evaluated. We investigated the influence of short-term intensive lipid-lowering treatment on quantitative and qualitative changes in plaque components of non-culprit lesions in patients with acute coronary syndrome. MATERIALS AND METHODS This was a prospective, ra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2012