The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes.
نویسندگان
چکیده
BACKGROUND The accuracy and efficacy of the Medtronic Diabetes (Northridge, CA) Real-Time (RT)-Continuous Glucose Monitoring (CGM) sensor were analyzed in 72 subjects with type 1 diabetes. METHODS This was a retrospective analysis of 60,050 temporally paired data points (sensor and glucose meter values) obtained during the course of an outpatient ambulatory study evaluating the efficacy of a sensor-augmented pump system in adults and adolescents. Subjects uploaded sensor values and self-monitoring blood glucose data to the CareLink Clinical Application (Medtronic Diabetes) via the Internet, every 2 weeks during the course of the study. RESULTS The overall percentage of sensor readings within +/-20% or +/-30% agreement of reference glucose readings was 75.6% and 86.8%, respectively. The highest rate of agreement occurred in the 240-400 mg/dL range, where 79.9% of sensor readings were within +/-20% of meter values and 91.5% of sensor readings were within 30% of meter values. The mean absolute relative difference for all subjects was 15.8%, and the median absolute relative difference was 10.9%. The bias was -2.13 mg/dL. Paired glucose measurements from the RT-CGM and meter demonstrated that 95.9% of paired points in the overall subject population fell in zones A and B of the Clarke Error Grid. Consensus Error Grid Analysis established that 99.2% of paired data points were in zones A and B. CONCLUSIONS This study reports the accuracy of a continuous glucose sensor with a large number of paired data points (60,050). RT-CGM is safe and well tolerated and provides readings that are in close agreement with glucose meter values.
منابع مشابه
Performance of a new real‐time continuous glucose monitoring system: A multicenter pilot study
AIMS/INTRODUCTION The present study aimed to investigate the performance of a new real-time continuous glucose monitoring system. MATERIALS AND METHODS Interstitial glucose levels were monitored for 7 days in 63 patients with type 1 or type 2 diabetes using the Medtrum A6 TouchCare® CGM System. Venous blood was collected on a randomized day of the wear period. Plasma glucose levels were measu...
متن کاملImprovement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial.
OBJECTIVE Hypoglycemia and wide glucose excursions continue to be major obstacles to achieving target HbA(1c) values and the associated reductions in long-term complications (and economic costs) in people with insulin-treated diabetes. In this study we evaluated the accuracy, safety, and clinical effectiveness of a continuous glucose-sensing device. RESEARCH DESIGN AND METHODS A total of 91 i...
متن کاملReal-time glucose sensors in children and adolescents with type-1 diabetes.
The increased availability of continuous glucose sensors is likely to have a significant impact on pediatric diabetes therapy and education in the future. While a recent meta-analysis of retrospective first-generation Holter-type sensors was not able to show advantages compared to self-monitoring of blood glucose levels, this review focuses on current real-time sensors. Our own experience with ...
متن کاملReal-Time Improvement of Continuous Glucose Monitoring Accuracy
OBJECTIVE Reliability of continuous glucose monitoring (CGM) sensors is key in several applications. In this work we demonstrate that real-time algorithms can render CGM sensors smarter by reducing their uncertainty and inaccuracy and improving their ability to alert for hypo- and hyperglycemic events. RESEARCH DESIGN AND METHODS The smart CGM (sCGM) sensor concept consists of a commercial CG...
متن کاملJDRF randomized clinical trial to assess the efficacy of real-time continuous glucose monitoring in the management of type 1 diabetes: research design and methods.
BACKGROUND While real-time (RT) continuous glucose monitoring (CGM) systems may revolutionize treatment of type 1 diabetes (T1D), there is insufficient evidence currently available to support widespread utilization of these devices. The Juvenile Diabetes Research Foundation (JDRF) CGM Study Group developed a randomized clinical trial to determine if RT-CGM can improve glycemic control and quali...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Diabetes technology & therapeutics
دوره 10 5 شماره
صفحات -
تاریخ انتشار 2008