FSI Analysis of a healthy and a stenotic human trachea under impedance-based boundary conditions.

نویسندگان

  • M Malvè
  • A Pérez del Palomar
  • S Chandra
  • J L López-Villalobos
  • A Mena
  • E A Finol
  • A Ginel
  • M Doblaré
چکیده

In this work, a fluid-solid interaction (FSI) analysis of a healthy and a stenotic human trachea was studied to evaluate flow patterns, wall stresses, and deformations under physiological and pathological conditions. The two analyzed tracheal geometries, which include the first bifurcation after the carina, were obtained from computed tomography images of healthy and diseased patients, respectively. A finite element-based commercial software code was used to perform the simulations. The tracheal wall was modeled as a fiber reinforced hyperelastic solid material in which the anisotropy due to the orientation of the fibers was introduced. Impedance-based pressure waveforms were computed using a method developed for the cardiovascular system, where the resistance of the respiratory system was calculated taking into account the entire bronchial tree, modeled as binary fractal network. Intratracheal flow patterns and tracheal wall deformation were analyzed under different scenarios. The simulations show the possibility of predicting, with FSI computations, flow and wall behavior for healthy and pathological tracheas. The computational modeling procedure presented herein can be a useful tool capable of evaluating quantities that cannot be assessed in vivo, such as wall stresses, pressure drop, and flow patterns, and to derive parameters that could help clinical decisions and improve surgical outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FSI analysis of a human trachea before and after prosthesis implantation.

In this work we analyzed the response of a stenotic trachea after a stent implantation. An endotracheal stent is the common treatment for tracheal diseases such as stenosis, chronic cough, or dispnoea episodes. Medical treatment and surgical techniques are still challenging due to the difficulties in overcoming potential complications after prosthesis implantation. A finite element model of a d...

متن کامل

Unsteady flow and mass transfer in models of stenotic arteries considering fluid-structure interaction

In this work the unsteady non-Newtonian blood flow and mass transfer in symmetric and non-symmetric stenotic arteries are numerically simulated considering the fluid-structure interaction (FSI) using the code ADINA. Blood with hyperviscosity syndrome is considered and hyperelastic Mooney–Rivlin model is used for the compliant arterial wall. The inlet boundary condition of imposed velocity or pr...

متن کامل

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

متن کامل

Impact of Blood Vessel Wall Flexibility on the Temperature and Concentration Dispersion

The analysis of solute and thermal dispersion in pulsatile flow through the stenotic tapered blood vessel is presented. The present problem is an extension of the work done by Ramana et al. who considered the time-invariant arterial wall. In the present model, the flexible nature of the arterial wall through the obstruction (called stenosis) is considered and it is achieved with the he...

متن کامل

Simulating cyclic artery compression using a 3D unsteady model with fluid–structure interactions

High pulsating blood pressure and severe stenosis make fluid–structure interaction (FSI) an important role in simulating blood flow in stenotic arteries. A three-dimensional nonlinear model with FSI and a numerical method using GFD are introduced to study unsteady viscous flow in stenotic tubes with cyclic wall collapse simulating blood flow in stenotic carotid arteries. The Navier–Stokes equat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 133 2  شماره 

صفحات  -

تاریخ انتشار 2011