SU-E-T-182: Delivery Verification of Tomotherapy Treatments Using Exit Detector Sinograms: A Phantom Study.
نویسندگان
چکیده
PURPOSE The objective of this study was to use a liquid water female body phantom to investigate the feasibility of using helical Tomotherapy's exit detector data sinograms (EDDS) for quality assurance of Tomotherapy treatments. METHODS Delivery Verification software (DV-Tool), described by Kapatoes et al., uses EDDS and daily mega-voltage-CT images for delivery sinogram reconstruction and subsequent dose computations. These dose distributions should reflect variations in patient's anatomy and machine delivery. Phantom was used to verify the robustness of the DV-Tool for machine consistency over 2months, and sensitivity to weight loss and setup errors. Weight loss simulations were done by removing layers of bolus from the phantom's pelvis. Setup errors were simulated by performing known table shifts before the treatment. Two treatment plans simulating a breast and gynecological treatment plans were used for these evaluations. Reconstructed doses and dose volume histograms (DVHs) were analyzed in comparison to the plan DVHs by scaling the reconstructed PTV mean dose (PTV-MD) to match the plan. PTV-MD differences before and after machine output adjustments were evaluated. RESULTS Machine consistency check of gynecological plan revealed that the deviations were greater (±5%) during the week prior to target replacement. After output adjustments, the deviations for breast and gynecological plans agreed within ±1.0% and ±2.5%, respectively. Weight loss on the gynecological plan showed a correlation (R2=0.998) between lost thickness and increasing PTV-MD by approximately 5%/cm. Setup errors on the breast plan showed broadening shoulder of the PTV DVH for shifts greater than 5mm. Volume at 20Gy for the right lung increased by 6% for 10mm shifts in both x and z directions. CONCLUSIONS The DV-Tool is sensitive to simulated weight loss, setup errors, and machine output. Exit detector data and the DV-Tool have great potential for monitoring patient's delivered treatments. However, clinical workflow needs to be established.
منابع مشابه
On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom.
For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements. A new method is propo...
متن کاملFast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy
BACKGROUND Patient-specific dose verification for treatment planning in helical tomotherapy is routinely performed using a homogeneous virtual water cylindrical phantom of 30 cm diameter and 18 cm length (Cheese phantom). Because of this small length, treatment with total marrow irradiation (TMI) requires multiple deliveries of the dose verification procedures to cover a wide range of the targe...
متن کاملDose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers
PURPOSE To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered for the patients during treatments. MATERIALS AND METHODS A pixel-segmented ionisation chamber device, IMRT MatriXX™ and Multicube™ phantom from IBA were used on ten selected Tomotherapy IMRT/IGRT head and ne...
متن کاملA feasibility study of dynamic verification for tumor target delineation and dose delivery using a six degrees of freedom motion phantom
Background: The dynamic phantom is one of the best tools to study the impact of motion on tumor target delineation and absorbed dose verification during dose delivery. Materials and Methods: this study, a 6-DOF (degrees of freedom) phantom was designed following the stacked serial kinematics and assembled by six commercial motion stages to generate 6-DOF motion, which were RotX (pitch, around X...
متن کاملAbstractID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT
ID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT Purpose: To evaluate the potential for Co-60 based tomotherapy including dose delivery and mega-voltage CT (MVCT). Tomotherapy is a rotational implementation of IMRT that provides highly conformal doses and patient setup verification using MVCT. Current tomotherapy is limited to linear accelerators. This poster present...