Comparison of techniques for measuring pulse-wave velocity in the rat.
نویسندگان
چکیده
We evaluated methods for measuring average and regional pulse-wave velocity along the full length of the aorta in 18-mo-old ether-anesthetized male spontaneously hypertensive rats. Catheter-tip manometers were placed in the ascending and descending thoracic aorta via the right carotid and left femoral arteries, respectively. As the distal catheter was withdrawn at 1-cm intervals, the relationship between the distal catheter insertion distance and distance between transducers was determined from the intercept of the insertion distance vs. transmission delay regression line. Methods that assessed the foot-to-foot time delay between pressures accurately predicted the separation between catheters (measured distance of 1.43 cm; intercept of 1.40 +/- 0.5 cm; P = not significant) were highly reproducible (coefficient of variation of 2.3% for repeated measurements) and showed minimal variability (range 509 +/- 30 to 600 +/- 29 cm/s) along the full length of the aorta. Methods that made use of the pressure-pressure transfer function were spatially (range of values along the aorta 367 +/- 17 to 722 +/- 39 cm/s) and temporally more variable, especially during vasoconstriction with methoxamine, due to the effects of reflected waves.
منابع مشابه
Pulmonary artery stiffness assessed by velocity-encoding MRI: comparison of techniques
Introduction The pulmonary artery (PA) plays an essential role in smoothing the transition from right-ventricular pulsatile flow to the nearly steady-flow at capillary level. The loss of PA compliance has considerable influence on elevated right-ventricle workload. MRI velocity-encoding is an effective technique for assessing pulse-wave-velocity (PWV) by measuring the disturbances in flow or ve...
متن کاملEvaluation of date extract on nerve conduction velocity in male rat
Abstract Introduction: neuropathy is a condition in which the peripheral nervous system is disrupted. The study of the effects of antioxidants on the performance improvement of this system is vital. This study was aimed at the investigation of the effects of date extract on nerve conduction velocity, distal latency, and wave height of the sciatic nerve in male rats. Materials and Methods: thi...
متن کاملAortic Compliance Evaluation: Comparison of Time Delay Algorithms
Aortic pulse wave velocity (PWV), a measurement of the flow pulse traveling along aorta as a surrogate for aortic compliance (AC), can be assessed using a single breath-hold through-plane phase contrast imaging technique. Accurate determination of the time delay (Δt) between flows in ascending and descending aorta is critical in PWV assessment. Various approaches have been studied, including me...
متن کاملValidation and application of empirical shear wave velocity models based on standard penetration test
Shear wave velocity is a basic engineering tool required to define dynamic properties of soils. In many instances it may be preferable to determine Vs indirectly by common in-situ tests, such as the Standard Penetration Test. Many empirical correlations based on the Standard Penetration Test are broadly classified as regression techniques. However, no rigorous procedure has been published for c...
متن کاملDifferent techniques for measuring aortic pulse wave velocity using magnetic resonance imaging
Introduction: The aorta is a basic determiner of the total systemic compliance. Maintaining the viscoelastic properties of the aorta is essential for proper biological functioning (1). Reduced aortic compliance has shown to correlate with different pathologic states. The assessment of aortic stiffness is increasingly used in the clinical assessment of cardiac patients. Invasive techniques using...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 82 1 شماره
صفحات -
تاریخ انتشار 1997