Patient radiation doses in paediatric interventional cardiology procedures: a review.
نویسندگان
چکیده
A large number of investigations into the radiation doses from x-ray guided interventional cardiology procedures in children have been carried out in recent years. A review was conducted of these studies, gathering data on kerma area product (P KA), fluoroscopic screening time (FT), air kerma, and estimates of effective dose and organ doses. The majority of studies focus on P KA and FT with no estimation of dose to the patient. A greater than ten-fold variation in average P KA was found between different studies, even where data were stratified by patient age or weight. Typical values of P KA were 0.6-10 Gy · cm2 (<1 year/10 kg), 1.5-30 Gy · cm2 (1-5 years), 2-40 Gy · cm2 (5-10 years), 5-100 Gy · cm2 (10-16 years) and 10-200 Gy · cm2 (>16 years). P KA was lowest for heart biopsy (0.3-10 Gy · cm2 for all ages combined) and atrial septostomy (0.4-4.0 Gy · cm2), and highest for pulmonary artery angioplasty (1.5-35 Gy · cm2) and right ventricular outflow tract dilatation (139 Gy · cm2). Most estimates of patient dose were in the form of effective dose (typically 3-15 mSv) which is of limited usefulness in individualised risk assessment. Few studies estimated organ doses. Despite advances in radiation protection, recent publications have reported surprisingly large doses, as represented by P KA and air kerma. There is little indication of a fall in these dose indicators over the last 15 years. Nor is there much suggestion of a fall in doses associated with the use of flat panel detectors, as opposed to image intensifiers. An assessment of the impact of radiation dose in the context of overall patient outcome is required.
منابع مشابه
Patient dose values during interventional cardiology examinations in Yazd hospital, Iran
Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...
متن کاملPatient Radiation Doses in Interventional Cardiology Procedures
Interventional cardiology procedures result in substantial patient radiation doses due to prolonged fluoroscopy time and radiographic exposure. The procedures that are most frequently performed are coronary angiography, percutaneous coronary interventions, diagnostic electrophysiology studies and radiofrequency catheter ablation. Patient radiation dose in these procedures can be assessed either...
متن کاملStaff dose assessment from coronary angiography
Background: Interventional cardiology procedures such as coronary angiography (CA) and percutaneous transluminal coronary angiography (PTCA) has been increased recent years. The purpose of this study was to measurement of effective dose to cardiology staffs who operate near the patient and are exposed to non-uniform radiation field due to patient scattered radiation. Materials and Methods: This...
متن کاملEvaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran
Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...
متن کاملRadiation-Induced Noncancer Risks in Interventional Cardiology: Optimisation of Procedures and Staff and Patient Dose Reduction
Concerns about ionizing radiation during interventional cardiology have been increased in recent years as a result of rapid growth in interventional procedure volumes and the high radiation doses associated with some procedures. Noncancer radiation risks to cardiologists and medical staff in terms of radiation-induced cataracts and skin injuries for patients appear clear potential consequences ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of radiological protection : official journal of the Society for Radiological Protection
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2016