Flow cytometric ion detection with plasticized poly(vinyl chloride) microspheres containing selective lonophores.
نویسندگان
چکیده
The use of flow cytometry as a rapid, high-throughput diagnostic tool for the analysis of ions is described. Monodisperse, uniform microspheres, which obey bulk optode theory and are governed by bulk extraction processes rather than surface phenomena, were prepared under mild, nonreactive conditions using a sonic stream particle casting apparatus. As an initial example demonstrating the utility of this approach, microspheres that contained a H+-selective fluorescent chromoionophore (ETH 5294), a cation-exchanger (NaTFPB), and either a highly sodium-selective (sodium ionophore X) or a potassium-selective ionophore (BME-44) were prepared. Separate solution analysis of sodium- and potassium-selective microspheres resulted in the generation of functional response curves using peak channel fluorescence intensities. The selectivity observed for both types of particles is sufficient for the clinical determination of Na+ and K+. Furthermore, sodium- and potassium-selective microspheres were analyzed in parallel using sodium sample solutions, resulting in the successful determination of sodium ion concentrations and providing important information about the selectivity of the potassium-selective sensors over sodium. This work demonstrates the potential applicability of flow cytometry as a means for developing multiplexed, rapid, high-throughput analyses for clinically relevant ions.
منابع مشابه
Chromium (III) ion selective electrode based on di(benzylamino)glyoxime
A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of
متن کاملFlow-Injection Amperometric Determination of Tacrine based on Ion Transfer across a Water–Plasticized Polymeric Membrane Interface
A flow-injection pulse amperometric method for determining tacrine, based on ion transfer across a plasticized poly(vinyl chloride) (PVC) membrane, was developed. A four-electrode potentiostat with ohmic drop compensation was used, while a flow-through cell incorporated the four electrodes and the membrane, which contained tetrabutylammonium tetraphenylborate. The influence of the applied poten...
متن کاملFlow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine
A flow-injection coulometric method for the determination of chlorpromazine based on ion transfer into a plasticized poly(vinyl chloride) (PVC) membrane, was developed. The detector used consists of a flow-through cell that incorporates a plasticized poly(vinyl chloride) (PVC) membrane which contains tetrabutylammonium tetraphenylborate as electrolyte. The membrane is located between the flowin...
متن کاملColloidal titration of aqueous zirconium solutions with poly(vinyl sulfate) by potentiometric endpoint detection using a toluidine blue selective electrode.
Zirconium oxy-salts were hydrolyzed to form positively charged polymer or cluster species in acidic solutions. The zirconium hydrolyzed polymer was found to react with a negatively charged polyelectrolyte, such as poly(vinyl sulfate), and to form a stoichiometric polyion complex. Thus, colloidal titration with poly(vinyl sulfate) was applied to measure the zirconium concentration in an acidic s...
متن کاملStripping analysis of nanomolar perchlorate in drinking water with a voltammetric ion-selective electrode based on thin-layer liquid membrane.
A highly sensitive analytical method is required for the assessment of nanomolar perchlorate contamination in drinking water as an emerging environmental problem. We developed the novel approach based on a voltammetric ion-selective electrode to enable the electrochemical detection of "redox-inactive" perchlorate at a nanomolar level without its electrolysis. The perchlorate-selective electrode...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
 
دوره 74 20 شماره
صفحات -
تاریخ انتشار 2002