Diagnostic accuracy of the Xpert MTB/RIF assay for extrapulmonary and pulmonary tuberculosis when testing non-respiratory samples: a systematic review

نویسندگان

  • Laura Maynard-Smith
  • Natasha Larke
  • Jurgens A Peters
  • Stephen D Lawn
چکیده

BACKGROUND Although the evidence base regarding the use of the Xpert MTB/RIF assay for diagnosis of pulmonary tuberculosis (TB) when testing respiratory samples is well established, the evidence base for its diagnostic accuracy for extrapulmonary and sputum-scarce pulmonary TB when testing non-respiratory samples is less clearly defined. METHODS A systematic literature search of 7 electronic databases (Medline, EMBASE, ISI Web of Science, BIOSIS, Global Health Database, Scopus and Cochrane Database) was conducted to identify studies of the diagnostic accuracy of the Xpert assay when testing non-respiratory samples compared with a culture-based reference standard. Data were extracted and study quality was assessed using the QUADAS-2 tool. Sensitivities and specificities were calculated on a per-sample basis, stratified by sample type and smear microscopy status and summarised using forest plots. Pooled estimates were calculated for groups with sufficient data. RESULTS Twenty-seven studies with a total of 6,026 non-respiratory samples were included. Among the 23 studies comparing Xpert and culture done on the same samples, sensitivity was very heterogeneous with a median sensitivity of 0.83 (IQR, 0.68-0.94) whereas specificities were typically very high (median, 0.98; IQR, 0.89-1.00). The pooled summary estimates of sensitivity when testing smear-positive and smear-negative samples were 0.95 (95% CI 0.91-1.00) and 0.69 (95% CI 0.60-0.80), respectively. Pooled summary estimates of sensitivity varied substantially between sample types: lymph node tissue, 0.96 (95% CI, 0.72-0.99); tissue samples of all types, 0.88 (95% CI, 0.76-0.94); pleural fluid, 0.34 (95% CI, 0.24-0.44); gastric aspirates for diagnosis of sputum-scarce pulmonary TB, 0.78 (IQR, 0.68 - 0.85). Median sensitivities when testing cerebrospinal fluid and non-pleural serous fluid samples were 0.85 (IQR, 0.75-1.00) and 0.67 (IQR, 0.00-1.00), respectively. CONCLUSION Xpert detects with high specificity the vast majority of EPTB cases with smear-positive non-respiratory samples and approximately two-thirds of those with smear-negative samples. Xpert is a useful rule-in diagnostic test for EPTB, especially when testing cerebrospinal fluid and tissue samples. In addition, it has a high sensitivity for detecting pulmonary TB when using gastric aspirate samples. These findings support recent WHO guidelines regarding the use of Xpert for TB diagnosis from non-respiratory samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid diagnosis of tuberculosis using Xpert MTB/RIF assay - Report from a developing country

OBJECTIVE To evaluate the diagnostic accuracy of the Xpert MTB/RIF assay for the detection of M. tuberculosis in pulmonary and extrapulmonary specimens and to compare it with conventional techniques. METHODS During a period of 10 months from December 2012 through September 2013, two hundred and forty five clinically TB suspects were enrolled for Xpert MTB\RIF assay. The cohort comprised of 20...

متن کامل

Performance of real-time PCR Xpert ®MTB/RIF in diagnosing extrapulmonary tuberculosis.

The real time PCR Xpert ® MTB/RIF is fundamental for rapid diagnosis in paucibacillary respiratory samples and for the detection of multidrug-resistant TB cases. This paper aimed to determine its performance on different extrapulmonary samples. We determined sensitivity, specificity, positive and negative predictive value on respiratory and non-respiratory samples collected from January 2010 to...

متن کامل

Xpert MTB/RIF assay for the diagnosis of extrapulmonary tuberculosis: a systematic review and meta-analysis.

Xpert MTB/RIF (Cepheid, Sunnyvale, CA, USA) is endorsed for the detection of pulmonary tuberculosis (TB). We performed a systematic review and meta-analysis to assess the accuracy of Xpert for the detection of extrapulmonary TB. We searched multiple databases to October 15, 2013. We determined the accuracy of Xpert compared with culture and a composite reference standard (CRS). We grouped data ...

متن کامل

Rapid and effective diagnosis of tuberculosis and rifampicin resistance with Xpert MTB/RIF assay: a meta-analysis.

OBJECTIVES Xpert MTB/RIF (Cepheid) assay has been introduced for the diagnosis of tuberculosis (TB) and RIF-resistance. The meta-analysis was used to establish the overall accuracy of Xpert MTB/RIF assay for diagnosing TB and RIF-resistance. METHODS Based on comprehensive searches of the Pubmed and Embase, we identified outcome data from all articles estimating diagnostic accuracy with Xpert ...

متن کامل

Evaluation of Xpert MTB/RIF in detection of pulmonary and extrapulmonary tuberculosis cases in China

Background: To evaluate the performance of Xpert MTB/RIF assay for direct detection of Mycobacterium tuberculosis (Mtb) and rifampin resistance in pulmonary and extrapulmonary tuberculosis (TB) patients in China. Material/Methods: We prospectively enrolled 506 TB patients to evaluate sensitivity and specificity of Xpert MTB/ RIF by comparing with Mtb culture, fluorescent staining smear microsco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014