Phase-contrast MRI volume flow - a comparison of breath held and navigator based acquisitions

نویسندگان

  • Charlotta Andersson
  • Johan Kihlberg
  • Tino Ebbers
  • Lena Lindström
  • Carl-Johan Carlhäll
  • Jan E. Engvall
چکیده

BACKGROUND Magnetic Resonance Imaging (MRI) 2D phase-contrast flow measurement has been regarded as the gold standard in blood flow measurements and can be performed with free breathing or breath held techniques. We hypothesized that the accuracy of flow measurements obtained with segmented phase-contrast during breath holding, and in particular higher number of k-space segments, would be non-inferior compared to navigator phase-contrast. Volumes obtained from anatomic segmentation of cine MRI and Doppler echocardiography were used for additional reference. METHODS Forty patients, five women and 35 men, mean age 65 years (range 53-80), were randomly selected and consented to the study. All underwent EKG-gated cardiac MRI including breath hold cine, navigator based free-breathing phase-contrast MRI and breath hold phase-contrast MRI using k-space segmentation factors 3 and 5, as well as transthoracic echocardiography within 2 days. RESULTS In navigator based free-breathing phase-contrast flow, mean stroke volume and cardiac output were 79.7 ± 17.1 ml and 5071 ± 1192 ml/min, respectively. The duration of the acquisition was 50 ± 6 s. With k-space segmentation factor 3, the corresponding values were 77.7 ml ± 17.5 ml and 4979 ± 1211 ml/min (p = 0.15 vs navigator). The duration of the breath hold was 17 ± 2 s. K-space segmentation factor 5 gave mean stroke volume 77.9 ± 16.4 ml, cardiac output 5142 ± 1197 ml/min (p = 0.33 vs navigator), and breath hold time 11 ± 1 s. Anatomical segmentation of cine gave mean stroke volume and cardiac output 91.2 ± 20.8 ml and 5963 ± 1452 ml/min, respectively. Echocardiography was reliable in 20 of the 40 patients. The mean diameter of the left ventricular outflow tract was 20.7 ± 1.5 mm, stroke volume 78.3 ml ± 15.2 ml and cardiac output 5164 ± 1249 ml/min. CONCLUSIONS In forty consecutive patients with coronary heart disease, breath holding and segmented k-space sampling techniques for phase-contrast flow produced stroke volumes and cardiac outputs similar to those obtained with free-breathing navigator based phase-contrast MRI, using less time. The values obtained agreed fairly well with Doppler echocardiography while there was a larger difference when compared with anatomical volume determinations using SSFP (steady state free precession) cine MRI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Navigator gated high temporal resolution tissue phase mapping of myocardial motion.

Data acquisition for phase contrast velocity mapping of myocardial motion is typically based on multiple breath-held 2D measurements with limited acquisition duration and consequently relatively poor temporal resolution. In order to overcome the limitations of breath-hold acquisitions, an improved navigator-guided technique was implemented based on 2 navigator signals within each cardiac cycle ...

متن کامل

The effects of breath-holding on pulmonary regurgitation measured by cardiovascular magnetic resonance velocity mapping

BACKGROUND Pulmonary regurgitation is a common and clinically important residual lesion after repair of tetralogy of Fallot. Cardiovascular magnetic resonance (CMR) phase contrast velocity mapping is widely used for measurement of pulmonary regurgitant fraction. Breath-hold acquisitions, usually acquired during held expiration, are more convenient than the non-breath-hold approach, but we hypot...

متن کامل

Real-time flow MRI of the aorta at a resolution of 40 msec.

PURPOSE To evaluate a novel real-time phase-contrast magnetic resonance imaging (MRI) technique for the assessment of through-plane flow in the ascending aorta. MATERIALS AND METHODS Real-time MRI was based on a radial fast low-angle shot (FLASH) sequence with about 30-fold undersampling and image reconstruction by regularized nonlinear inversion. Phase-contrast maps were obtained from two (i...

متن کامل

Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitions

BACKGROUND Two-dimensional, unidirectionally encoded, cardiovascular magnetic resonance (CMR) velocity mapping is an established technique for the quantification of blood flow in large vessels. However, it requires an operator to correctly align the planes of acquisition. If all three directional components of velocity are measured for each voxel of a 3D volume through the phases of the cardiac...

متن کامل

Technique for retrospective respiratory and cardiac-gated phase contrast flow measurements

Background The effect of the respiratory cycle on flow is well documented for cerebrospinal venous return [1] and CSF flow [2]. However, cranial phase contrast (PC) MR flow measurements neglect the influence of respiration. Breath-held acquisitions are possible, but mask physiological flow changes that occur during active respiration. Here we demonstrate a technique to evaluate the effects of a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC medical imaging

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016