Accuracy and Reliability of Continuous Glucose Monitoring in the Intensive Care Unit: A Head-to-Head Comparison of Two Subcutaneous Glucose Sensors in Cardiac Surgery Patients

نویسندگان

  • Sarah E. Siegelaar
  • Temo Barwari
  • Jeroen Hermanides
  • Wim Stooker
  • Peter H.J. van der Voort
  • J. Hans DeVries
چکیده

Hyperglycemia, hypoglycemia, and glucose variability are common during intensive care unit (ICU) stay and are associated with increased mortality (1–3). Continuous glucose monitoring (CGM) is a promising tool to assist glucose control, but the accuracy and reliability of these devices in critically ill patients is uncertain (4,5). Therefore, we studied two different CGM devices postoperatively in cardiac surgery patients in an investigator-initiated trial. We placed two CGM devices (Guardian RT, Medtronic Minimed; FreeStyle Navigator, Abbott Diabetes Care) subcutaneously in the abdominal wall before surgery in 60 patients. This is the first time the Navigator has been studied in an ICU setting. Both devices were calibrated simultaneously upon arrival at the ICU after surgery. Further calibrations were performed according to manufacturers’ instructions. An arterial blood glucose value was measured with an AccuChek device (Performa II, Roche/Hitachi) as a reference value every 2 hours. Relative absolute deviation (RAD) between reference and sensor glucose values was calculated in six 5-min intervals after the time of the reference glucose to assess a possible delay. Of the 60 patients, 48weremale with a median (range) age of 65 years (25–85), and 16 were diagnosed with type 2 diabetes. The median (IQR) maximum Sequential Organ Failure Assessment score and ICU stay were 6.0 (5.3–7.0) and 23.0 hours (19.0–45.8), andmean (SD) glucose was 8.2 (2.1) mmol/L. We obtained 1,017 reference glucose values of which 77.8% could be paired with a Guardian and 91.8% with a Navigator value in the first interval. Missing values indicate technical problems with the device: signal loss (Guardian: 19 patients; Navigator: 1 patient), sensor failure (Guardian: 7 patients; Navigator: 2 patients), interruption of realtime representation of glucose values after delayed recalibration (Guardian) or temporarily failure of data-recording (Navigator: 4 patients). Median (IQR) RAD was significantly smaller for Navigator compared with Guardian glucose measurements at intervals 0–4 and 5–9 min after the reference glucose (11% [8–16] and 10% [8–16] compared with 14% [11–18] and 14% [11–17], P 5 0.05 and P 5 0.001, Wilcoxon signed rank test). The lowest RAD of the Navigator was observed 5– 9 min after reference glucose, but no significant effect of time was seen (P5 0.74, repeated measures ANOVA). The accuracy of the Guardian did show a delay with the lowest RAD after 15–19 min (11% [8–13], P 5 0.01). There was no consistency in underor overestimation of the reference glucose values. No separate analyses to assess accuracy during hypoglycemia were performed because no severe hypoglycemia (#2.2 mmol/L) was measured and only 34 of 1,017 reference glucose values were mildly hypoglycemic (#4.7 mmol/L) (1). We report that the FreeStyle Navigator CGM system performed better than the Guardian RT in accuracy as well as reliability in postoperative cardiac surgery patients during ICU stay. Remarkably, the RAD of both sensors was quite good compared with reported data for outpatients. According to these results, we conclude that this device can be used in this group of ICU patients characterized by relatively low disease severity scores and low mortality rates. Whether or not the use of CGM improves glycemic control and mortality needs further research.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of dexamethasone on the reduction of airway edema and the success of extubation in patients with head and neck surgery admitted to the intensive care unit

Background: The decision to extubate the patient is crucial and challenging. The use of corticosteroids to reduce airway edema and extubation failure in intensive care patients is debatable. Methods: In an observational prospective cohort study from April 2021 to July 2021, 110 patients undergoing head and neck surgery at Imam Khomeini Hospital's special wards were enrolled. Inclusion criteria...

متن کامل

Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)

OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...

متن کامل

Point accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study

INTRODUCTION There is a need for continuous glucose monitoring in critically ill patients. The objective of this trial was to determine the point accuracy and reliability of a device designed for continuous monitoring of interstitial glucose levels in intensive care unit patients. METHODS We evaluated point accuracy by comparing device readings with glucose measurements in arterial blood by u...

متن کامل

Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial

BACKGROUND Continuous glucose monitoring (CGM) has not yet been implemented in the intensive care unit (ICU) setting. The purpose of this study was to evaluate reliability, feasibility, nurse acceptance and accuracy of the Medtronic Sentrino(®) CGM system in critically ill patients. METHODS Sensors were inserted into the subcutaneous tissue of the patient's thigh, quantifying interstitial glu...

متن کامل

Incidence of pressure ulcer in patients who were admitted to open heart cardiac surgery intensive care unit

Background and aims: Cardiac surgery patients are at high risk of pressure ulcers. In the present study, we determined the incidence of pressure ulcer in patients who were admitted to open heart cardiac surgery intensive care unit and related risk factors. Methods: With using convenience sampling all the eligible patients who were admitted to Boali cardiac surgery during June to August 2015 we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2011