Fully automated deconvolution method for on-line analysis of time-resolved fluorescence spectroscopy data based on an iterative Laguerre expansion technique.

نویسندگان

  • Aditi S Dabir
  • Chintan A Trivedi
  • Yeontack Ryu
  • Paritosh Pande
  • Javier A Jo
چکیده

Time-resolved fluorescence spectroscopy (TRFS) is a powerful analytical tool for quantifying the biochemical composition of organic and inorganic materials. The potential of TRFS for tissue diagnosis has been recently demonstrated. To facilitate the translation of TRFS to the clinical arena, algorithms for online TRFS data analysis are essential. A fast model-free TRFS deconvolution algorithm based on the Laguerre expansion method has previously been introduced. One limitation of this method, however, is the need to heuristically select two parameters that are crucial for the accurate estimation of the fluorescence decay: the Laguerre parameter alpha and the expansion order. Here, a new implementation of the Laguerre deconvolution method is introduced, in which a nonlinear least-square optimization of the Laguerre parameter alpha is performed, and the optimal expansion order is selected based on a minimum description length criterion (MDL). In addition, estimation of the zero-time delay between the recorded instrument response and fluorescence decay is also performed based on normalized mean square error criterion (NMSE). The method is validated on experimental data from fluorescence lifetime standards, endogenous tissue fluorophores, and human tissue. The proposed automated Laguerre deconvolution method will facilitate online applications of TRFS, such as real-time clinical tissue diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel method for fast and robust estimation of fluorescence decay dynamics using constrained least-squares deconvolution with Laguerre expansion.

We report a novel method for estimating fluorescence impulse response function (fIRF) from noise-corrupted time-domain fluorescence measurements of biological tissue. This method is based on the use of high-order Laguerre basis functions and a constrained least-squares approach that addresses the problem of overfitting due to increased model complexity. The new method was extensively evaluated ...

متن کامل

Fast model-free deconvolution of fluorescence decay for analysis of biological systems.

For complex biological systems, conventional analysis of fluorescence intensity decay in terms of discrete exponential components cannot readily provide a true representation of the underlying fluorescence dynamics. We investigate an alternative nonparametric method for the analysis of time-resolved fluorescence data from biochemical and biological systems based on the expansion of fluorescence...

متن کامل

Optimizing Laguerre expansion based deconvolution methods for analysing bi-exponential fluorescence lifetime images.

Fast deconvolution is an essential step to calibrate instrument responses in big fluorescence lifetime imaging microscopy (FLIM) image analysis. This paper examined a computationally effective least squares deconvolution method based on Laguerre expansion (LSD-LE), recently developed for clinical diagnosis applications, and proposed new criteria for selecting Laguerre basis functions (LBFs) wit...

متن کامل

Towards unsupervised fluorescence lifetime imaging using low dimensional variable projection.

Analyzing large fluorescence lifetime imaging (FLIM) data is becoming overwhelming; the latest FLIM systems easily produce massive amounts of data, making an efficient analysis more challenging than ever. In this paper we propose the combination of a custom-fit variable projection method, with a Laguerre expansion based deconvolution, to analyze bi-exponential data obtained from time-domain FLI...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 2009