Reference ranges for LVEF and LV volumes from electrocardiographically gated 82Rb cardiac PET/CT using commercially available software.
نویسندگان
چکیده
UNLABELLED Electrocardiographic gating is increasingly used for (82)Rb cardiac PET/CT, but reference ranges for global functional parameters are not well defined. We sought to establish reference values for left ventricular ejection fraction (LVEF), end systolic volume (ESV), and end diastolic volume (EDV) using 4 different commercial software packages. Additionally, we compared 2 different approaches for the definition of a healthy individual. METHODS Sixty-two subjects (mean age +/- SD, 49 +/- 9 y; 85% women; mean body mass index +/- SD, 34 +/- 10 kg/m(2)) who underwent (82)Rb-gated myocardial perfusion PET/CT were evaluated. All subjects had normal myocardial perfusion and no history of coronary artery disease (CAD) or cardiomyopathy. Subgroup 1 consisted of 34 individuals with low pretest probability of CAD (<10%), and subgroup 2 comprised 28 subjects who had no atherosclerosis on a coronary CT angiogram obtained concurrently during the PET/CT session. LVEF, ESV, and EDV were calculated at rest and during dipyridamole-induced stress, using CardIQ Physio (a dedicated PET software) and the 3 major SPECT software packages (Emory Cardiac Toolbox, Quantitative Gated SPECT, and 4DM-SPECT). RESULTS Mean LVEF was significantly different among all 4 software packages. LVEF was most comparable between CardIQ Physio (62% +/- 6% and 54% +/- 7% at stress and rest, respectively) and 4DM-SPECT (64% +/- 7% and 56% +/- 8%, respectively), whereas Emory Cardiac Toolbox yielded higher values (71% +/- 6% and 65% +/- 6%, respectively, P < 0.001) and Quantitated Gated SPECT lower values (56% +/- 8% and 50% +/- 8%, respectively, P < 0.001). Subgroup 1 (low likelihood) demonstrated higher LVEF values than did subgroup 2 (normal CT angiography findings), using all software packages (P < 0.05). However, mean ESV and EDV at stress and rest were comparable between both subgroups (p = NS). Intra- and interobserver agreement were excellent for all methods. CONCLUSION The reference range of LVEF and LV volumes from gated (82)Rb PET/CT varies significantly among available software programs and therefore cannot be used interchangeably. LVEF results were higher when healthy subjects were defined by a low pretest probability of CAD than by normal CT angiography results.
منابع مشابه
Reference Ranges for LVEF and LV Volumes
Electrocardiographic gating is increasingly used for 82Rb cardiac PET/CT, but reference ranges for global functional parameters are not well defined. We sought to establish reference values for left ventricular ejection fraction (LVEF), end systolic volume (ESV), and end diastolic volume (EDV) using 4 different commercial software packages. Additionally, we compared 2 different approaches for t...
متن کاملComparison of measures of left ventricular function from electrocardiographically gated 82Rb PET with contrast-enhanced CT ventriculography: a hybrid PET/CT analysis.
UNLABELLED Because of the ultrashort tracer half-life and high positron energy of (82)Rb, PET images acquired with this tracer are noisier and of lower resolution than those obtained with other PET tracers. The validity of electrocardiographic gating using (82)Rb for assessment of left ventricular (LV) function is not well established. To support feasibility, we compared functional parameters f...
متن کاملCalculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET
BACKGROUND Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from stand...
متن کاملWHITE PAPER Validation of a deformable atlas-based left ventricular segmentation method for PET and SPECT: comparison to cardiac computed tomography angiography (CCTA) volumes
Gated myocardial perfusion SPECT and PET are commonly used to calculate left ventricular ejection fraction (LVEF) and assess left ventricular end diastolic (EDV) and end systolic volumes (ESV). A number of software methods have been developed to automatically calculate these parameters. In a previous work we compared the LV parameters (EF, EDV, ESV) for three software packages: MIMcardiac®, QGS...
متن کاملLeft ventricular functional assessment in murine models of ischemic and dilated cardiomyopathy using [18 F]FDG-PET: comparison with cardiac MRI and monitoring erythropoietin therapy
BACKGROUND We performed an initial evaluation of non-invasive ECG-gated [18 F]FDG-positron emission tomography (FDG-PET) for serial measurements of left ventricular volumes and function in murine models of dilated (DCM) and ischemic cardiomyopathy (ICM), and then tested the effect of erythropoietin (EPO) treatment on DCM mice in a preliminary FDG-PET therapy monitoring study. METHODS Mice dev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 51 6 شماره
صفحات -
تاریخ انتشار 2010