Temporal stability and precision of ventricular defibrillation threshold data.
نویسندگان
چکیده
Over 200 measurements of the minimum damped sinusoidal current and energy for transchest electrical ventricular defibrillation (ventricular defibrillation threshold) were made to determine the stability and precision of threshold data in 15 pentobarbital-anesthetized dogs. Threshold was determined by repeated trials of fibrillation and defibrillation with successive shocks of diminishing current, each 10% less than that of the preceding shock. The lowest shock intensity that defibrillated was defined as threshold. In three groups of five dogs each, threshold was measured at intervals of 60, 15, and 5 min over periods of 8, 5, and 1 h, respectively. Similar results were obtained for all groups. There was no significant change in mean threshold current with time. Owing to a decrease in transchest impedance, threshold delivered energy decreased by 10% during the first hour of testing. The standard deviations for threshold peak current and delivered energy in a given animal were 11% and 22% of their respective mean values. Arterial blood pH, Pco2, and Po2 averaged change of pH, PCO2 and PO2 were not significantly different from zero. The data demonstrate that ventricular defibrillation threshold is a stable physiological parameter that may be measured with reasonable precision.
منابع مشابه
Effect of pentobarbital anesthesia on ventricular defibrillation threshold in dogs.
The effect of pentobarbital anesthesia upon the minimal voltage and current required for electrical ventricular defibrillation (the defibrillation threshold) was investigated in dogs. Threshold current, energy, and charge in five dogs averaged 2 per cent, 13 per cent, and 6 per cent less under surgical levels of pentobarbital anesthesia than thresholds in the same animals in the awake, unanesth...
متن کاملEfficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS).
BACKGROUND Traditionally, a safety margin of at least 10 J between the maximum output of the pulse generator and the energy needed for ventricular defibrillation has been used because lower safety margins were associated with unacceptably high rates of failed defibrillation and sudden cardiac death. The Low Energy Safety Study (LESS) was a prospective, randomized assessment of the safety margin...
متن کاملEfficacy and Temporal Stability of Reduced Safety Margins for Ventricular Defibrillation
Background—Traditionally, a safety margin of at least 10 J between the maximum output of the pulse generator and the energy needed for ventricular defibrillation has been used because lower safety margins were associated with unacceptably high rates of failed defibrillation and sudden cardiac death. The Low Energy Safety Study (LESS) was a prospective, randomized assessment of the safety margin...
متن کاملAtrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.
OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...
متن کاملOptical mapping of ventricular defibrillation in isolated swine right ventricles: demonstration of a postshock isoelectric window after near-threshold defibrillation shocks.
BACKGROUND Investigators who studied ventricular defibrillation by use of optical mapping techniques failed to observe an initial defibrillation event (isoelectric window or quiescent period) shown by electrode mapping studies. This discrepancy has important implications for the mechanisms of defibrillation. The purpose of the present study was to demonstrate an optical equivalent of an isoelec...