Immunoassayof a1-AcidGlycoproteinin the Cobas Bio CentrifugalAnalyzer

نویسندگان

  • Catherine N. Verme
  • Thomas M. Ludden
  • Steven C. Harris
چکیده

There is an increasing demand for quantification of serum a1acid glycoprotein (AAG, orosomucoid) in studies evaluating the protein binding of highly bound basic drugs. This paper describes an adaptation of an automated immunoturbidimetric assay for this protein to the Cobas Bio centrifugal analyzer. Replicate analyses of aliquots from six different solutions were used in determining precision. We also analyzed 367 patients’ serum samples, induplicate,todetermine thedistributionofAAG in hospitalized patients. The intraand inter-run CVs ranged from 1.3% to 4.4% and from 0.6% to 6.6%, respectively. AAG concentrations in patients’ samples ranged from 0.38 to 3.16 gIL. Results by this method correlate well with those by radial immunodiffusion, with no significant amount of bias between the two methods. This immunoturbidimetric procedure is faster and less expensive than currently used radial immunodiffusion techniques, and precision is acceptable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoturbidimetric assays for serum apolipoproteins A1 and B using Cobas Bio centrifugal analyser.

Immunoturbidimetric assays for measuring the apolipoproteins A1 and B using the Cobas Bio centrifugal analyser are described. The methods were specific, offered good sensitivity (less than 0.05 g/l) and intrabatch variability, with coefficients of variation between 2.4% and 3.5%, and were cost effective. Reference ranges were calculated for a group of civil servants, aged 35 to 55 years.

متن کامل

Relationship between serum levels of fetuin-A with apo-A1, apo-B100, body composition and insulin resistance in patients with type 2 diabetes

  Background :Some results exist on fetuin-A as marker for vascular disease in type 2diabetes. We examined the relationship between serum fetuin-A with some factors, in patients with type 2 diabetes mellitus (T2DM).   Methods : From October 2012 to June 2013, a total of 131 T2DM patients were recruited and evaluated for various parameters including HOMA-IR, Apo-A1, Apo-B100, body fat percentage...

متن کامل

Evaluation of four gentamicin and tobramycin assay procedures for clinical laboratories.

Accuracy, precision, and clinical laboratory utility of the TDX (Abbott Laboratories), Auto-ICS (Beckman Instruments, Inc.), COBAS-Bio (Roche Analytical Instruments, Inc.) with reagent kits (Syva), and EMIT (Syva) for gentamicin and tobramycin serum assay were assessed. TDX, COBAS-Bio, and EMIT analytical systems showed a proportional bias of less than 10% for recovery studies and a coefficient...

متن کامل

Determination of free haemoglobin in serum by an automated assay using 4-aminophenazone and the Cobas Bio System.

A colorimetric method for the determination of free haemoglobin in human serum is described, using 4-aminophenazone as chromogen, and commercially available haemiglobin cyanide solutions as standards. The reaction system is suitable for manual measurements as well as determinations with a centrifugal analyser (Cobas Bio System). Accuracy, linearity and stability of the procedure is shown. A ref...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004