Upgrade of the Neutron Dose Measurement System at Bessy
نویسندگان
چکیده
Neutron radiation fields at synchrotron light sources are caused by bremsstrahlung from electron losses in accelerator components. Inside the enclosure and in transversal direction neutron and gamma radiation is of the same order of magnitude but high energy neutrons are much more penetrating. This causes outside the shielding neutron spectra with two broad maxima at about 1 MeV and 100 MeV. Standard Anderson-Braun or Leake neutron monitors measure thermalized neutrons in a proportional counter tube by nuclear reactions which limits the measurement range to neutron energies < 10 MeV. This implies two considerable systematic errors: Pulsed neutron beams causes dead-time losses due to the time structure of injections and the moderators are not sufficient to moderate high energy neutrons down to thermal energies. We determined and fixed these measurement errors by faster preamplifiers and by a more effective moderator developed by us, which expands the measurement range up to several GeV. Examples of the application at BESSY are presented.
منابع مشابه
Estimation of neutron and gamma dose in the MNSR research reactor
In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...
متن کاملRadiation Safety Assessment of the New Neutron Radiography System at Tehran Research Reactor
Recently, a new Neutron Radiography (NR) beam line has been designed, constricted, installed and tested based on the use of E-beam tube of Tehran Research Reactor (TRR). Initial tests have been shown that the system can be used for different samples and purposes such as nuclear plates and rods fuels. For this end the system need a suitable irradiation room which should be installed at the NR b...
متن کاملNeutron Contamination Unexpected Dose in Varian LINAC
Introduction: Neutron contamination is very harmful for the patients receiving radiation therapy due to the high relative biological effect of neutrons. Medical linear accelerators head are made up of materials with high atomic numbers, and High-energy photons interaction with heavy materials can produce neutron contamination. In this study, neutron equivalent dose, neutron spe...
متن کاملThe Variable pulse length Storage Ring (BESSY VSR) upgrade to BESSY II at Helmholtz-Zentrum Berlin (HZB)
The Variable pulse length Storage Ring (BESSY VSR) upgrade to BESSY II at Helmholtz-Zentrum Berlin (HZB) requires an upgrade on the RF systems in the form of highvoltage longitudinally focusing super conducting RF cavities of 1.5GHz and 1.75GHz. Coaxial RF power couplers capable of handling 13 kW peak power at standing wave operation, are required to provide an average power of 1.5 kW for both ...
متن کاملUnexpected dose and the biological effect of neutron contamination in linear accelerators
Employing High-energy photons in medical linear accelerators can lead to neutron contamination. The relative biological effect of neutrons is 20 times higher than photons. Consequently, its damage to the biological tissue is much higher and unobtrusive. In this study, we calculated neutron equivalent dose in a medical linear accelerator by the FLUKA Monte Carlo code system. The results show tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017