Deconvolution with correct sampling

نویسنده

  • P. Magain
چکیده

A new method for improving the resolution of astronomical images is presented. It is based on the principle that sampled data cannot be fully deconvolved without violating the sampling theorem. Thus, the sampled image should not be deconvolved by the total Point Spread Function, but by a narrower function chosen so that the resolution of the deconvolved image is compatible with the adopted sampling. Our deconvolution method gives results which are, in at least some cases, superior to those of other commonly used techniques : in particular, it does not produce ringing around point sources superimposed on a smooth background. Moreover, it allows to perform accurate astrometry and photometry of crowded fields. These improvements are a consequence of both the correct treatment of sampling and the recognition that the most probable astronomical image is not a flat one. The method is also well adapted to the optimal combination of different images of the same object, as can be obtained, e.g., from infrared observations or via adaptive optics techniques. Subject headings: Methods: Numerical Observational Data analysis Mâıtre de Recherches au Fonds National de la Recherche Scientifique (Belgium)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rééchantillonnage de l’échelle dans les algorithmes MCMC pour les problèmes inverses bilinéaires

This article presents an efficient method for improving the behavior of the MCMC sampling algorithm involved in the resolution of bilinear inverse problems. Blind deconvolution and source separation are among the applications that benefit from this improvement. The proposed method addresses the scale ambiguity inherent to bilinear inverse problems. Solving this type of problem within a Bayesian...

متن کامل

Deconvolution of Sub-pixeled Richardson-Lucy Algorithm

We introduce a Modiied Richardson-Lucy Algorithm for reducing data from the Subaru AO system. This new algorithm applies Magain's correct sampling approach to the Classical Richardson-Lucy algorithm. We have evaluated its performance for astronomical usage, appearance of the object and photometric accuracy, and compared our results to those obtained with a Classical Richardson-Lucy Algorithm.

متن کامل

Deconvolution enhanced Generalized Q-Sampling 2 and DSI deconvolution

For the purpose of the ISBI HARDI reconstruction challenge 2013 and for the heavyweight category, we reconstructed the diffusion datasets using two methods: a) Generalized Q-sampling Imaging 2 [1], [2] with spherical deconvolution [3],[4] (GQID), and b) Diffusion Spectrum Imaging with Deconvolution [5] (DSID). GQI2 provides a direct analytical formula to calculate the solid angle ODF (ψGQI2) of...

متن کامل

The application of compressive sampling to radio astronomy I: Deconvolution

Compressive sampling is a new paradigm for sampling, based on sparseness of signals or signal representations. It is much less restrictive than Nyquist-Shannon sampling theory and thus explains and systematises the widespread experience that methods such as the Högbom CLEAN can violate the Nyquist-Shannon sampling requirements. In this paper, a CS-based deconvolution method for extended sources...

متن کامل

Ultrasound compressive deconvolution with ℓP-Norm prior

It has been recently shown that compressive sampling is an interesting perspective for fast ultrasound imaging. This paper addresses the problem of compressive deconvolution for ultrasound imaging systems using an assumption of generalized Gaussian distributed tissue reflectivity function. The benefit of compressive deconvolution is the joint volume reduction of the acquired data and the image ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997