Measuring the shape and volume of an above-knee stump.

نویسندگان

  • T A Krouskop
  • D Dougherty
  • M I Yalcinkaya
  • A Muilenberg
چکیده

A set of design criteria for sensing the shape of an above-knee (AK) stump is presented and used as the basis for evaluating various shape sensing technologies. A mechanical probe type shape sensing system is described and its use in quantifying the external shape of the AK stump is discussed as it relates to generating a grid for finite element analysis in CAD/CAM studies and comparing the segmental volumes of the loaded and unloaded stump. This study also discusses a method that uses circumferential measurements to compute total and incremental volumes of the stump.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ilizarov Stump Lenthening Can Aggravate Phantom Limb Pain – a Case Report

Ilizarov is an accepted technique for lengthening short amputation stumps to improve prosthetic function andrehabilitation. The relation of stump lengthening and phantom limb pain (PLP) has not been reported in literature.We present here a case report of a transfemoral amputee who had a flare up of PLP following stump lengthening.He responded well to a combination of pharmacological therapy and...

متن کامل

A clinical standard of stump measurement and classification in lower limb amputees.

The dimensions and healing of 93 consecutive below-knee stumps were studied and based on observations a standard formula of stump classification was constructed (and discussed at the ISPO Meeting in Bologna 1980). Muscular atrophy and redistribution of oedema caused a mean reduction of calculated arbitrary stump volume of about 7% during the first 12 post-operative weeks accompanied by a change...

متن کامل

Prosthetic programme after above-knee amputation in children with sarcomata.

A programme for early mobilisation using a temporary prosthesis was evaluated in 17 children who had had an amputation above the knee for sarcomata. The temporary prosthesis had a performed adjustable polypropylene quadrilateral socket which was able to accommodate changes in the size of the stump during the first few months after amputation. The adjustable sockets were assembled onto wooden kn...

متن کامل

Design and Evaluation of a Magnetorheological Damper Based Prosthetic Knee

In this work, a magnetorheological (MR) damper based above-knee prosthesis is design and evaluated based on its performance in swing phase and in stance phase. Initially, a dynamic system model for swing phase of a prosthetic leg incorporating a single-axis knee with ideal MR damper was built. The dynamic properties of the damper are represented with Bingham parametric model. From Bingham model...

متن کامل

Knee Fusion or Above-The-Knee Amputation after Failed Two-Stage Reimplantation Total Knee Arthroplasty

Prosthetic joint infection (PJI) is a serious complication of total knee arthroplasty (TKA). Control of infection after a failed two-stage TKA is not always possible, and the resolution of infection may require an above-knee amputation (AKA) or a the-knee (KF). The purpose of this review is to determine which treatment method (AKA or KF) yields better function and ambulatory status for patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 1988