سند علمی

High Sensitivity Optically Pumped Quantum Magnetometer

چکیده

Quantum magnetometers based on optical pumping can achieve sensitivity as high as what SQUID-based devices can attain. In this paper, we discuss the principle of operation and the optimal design of an optically pumped quantum magnetometer. The ultimate intrinsic sensitivity is calculated showing that optimal performance of the magnetometer is attained with an optical pump power of 20 μW and an operation temperature of 48°C. Results show that the ultimate intrinsic sensitivity of the quantum magnetometer that can be achieved is 327 fT/Hz(½) over a bandwidth of 26 Hz and that this sensitivity drops to 130 pT/Hz(½) in the presence of environmental noise. The quantum magnetometer is shown to be capable of detecting a sinusoidal magnetic field of amplitude as low as 15 pT oscillating at 25 Hz.

اسناد مشابه

  • A high-sensitivity laser-pumped Mx magnetometer

    مقاله‌ی دسترسی آزاد۲۰۰۶The European Physical Journal DS.Groeger, G.Bison, J.-L.Schenker, R.Wynands
  • Optically pumped alkali magnetometers for biomedical applications

    سند علمی۲۰۱۲Antoine Weis

    20 Optically pumped atomic magnetometers measure the Larmor frequency νL at which the bulk magnetization of a spin-polarized alkali metal vapour in a glass cell precesses around the field of interest B0. !e precession frequency is related to the modulus of the magnetic field by ν

  • High Sample Rate Optically Pumped Helium Magnetometer

    مقاله۲۰۱۹Journal of Optoelectronical NanostructuresAbdorreza Asrar, Mohammad Javad Salehi, Mojtaba Servatkhah

    Optically pumped helium magnetometers are important instruments which have many applications in military, mass spectroscopy and space applications. In this paper, the working principles of helium magnetometers have been explained. There is also an introduction of a new method for

  • Advances in optically pumped He4 magnetometers : Resonance and nonresonance techniques

    سند علمی۲۰۱۶R. E. Slocum

    2014 Samples of optically pumped 23S1 helium atoms are currently studied in our laboratory for use in advanced magnetometer applications. The results of recent investigations of the effect of pumping beam orientation with respect to the observed magnetic field are presented in th

  • Study of He Rabi nutations by optically-pumped cesium magnetometers

    سند علمی۲۰۱۷Hans-Christian Koch, Georg Bison, Zoran Dragan Grujić, Werner Heil

    We describe a method for recording the Rabi nutation of nuclear spin polarized He by optically pumped cesium magnetometers. The measurement is performed by detecting the time-dependent magnetic field produced by the He magnetization. The observed signals are compared to theoretic

  • Al2O3 Ultra-Thin Films Deposited by PEALD for Rubidium Optically Pumped Atomic Magnetometers with On-Chip Photodiode

    مقاله‌ی دسترسی آزاد۲۰۲۳Coatings['Florival M. Cunha', 'Manuel F. Silva', 'Nuno M. Gomes', 'José Higino Correia', '']

    This communication shows the recipe for plasma-enhanced atomic layer deposition (PEALD) Al2O3 ultra-thin films with thicknesses below 40 nm. were deposited by PEALD to improve rubidium optically pumped magnetometers’ (OPMs) cell lifetime. requirement is due consumption of alkali