Development of an in vitro-based potency assay for anthrax vaccine.

نویسندگان

  • S F Little
  • W M Webster
  • B E Ivins
  • P F Fellows
  • S L Norris
  • G P Andrews
چکیده

The potency assay currently used to evaluate consistency of manufacture for the anthrax vaccine is contingent upon meeting specified parameters after statistical analysis of the percent survival and time to death of vaccinated guinea pigs after challenge with spores of a virulent strain of Bacillus anthracis. During the development of a new anthrax vaccine based upon recombinant protective antigen (rPA) adsorbed to aluminum hydroxide gel (Alhydrogel), we found that the serological response of female A/J mice, as measured by a quantitative anti-rPA IgG ELISA, may be an effective method to monitor a manufacturer's consistency for rPA-based vaccines. An advantage of the proposed in vitro-based potency assay is that it will not need stringent biosafety containment measures as required by the current guinea pig potency assay.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability and potency studies of anthrax vaccine (Bacillus anthracis 34F2 Sterne strain) in Iran

  For evaluation the stability and potency of anthrax vaccine prepared in Razi Vaccine and Serum Research Institute in Iran, samples of different batches of vaccine were kept at 4-8 °C (refrigerator), 20-25 °C (room temperature) and 37 °C (incubator).The viable spores/ml of vaccines were determined using plate–counting method before and after holding at different temperatures monthly. Vaccine p...

متن کامل

Designing of Immuno-capture ELISA assay kit for rabies vaccine potency

Background: Potency evaluation of rabies vaccine is a cheap, fast, high precision and consistent with ethical values is critical, so researchers have modified a variety of methods such as: National Institute of Health (NIH) method, Single Radial Immunodiffusion (SRID) and so on. The purpose of the present study was to replace an in vitro method consistent with medical ethics criteria instead of...

متن کامل

Evaluation of an anti-rPA IgG ELISA for measuring the antibody response in mice.

A recombinant protective antigen (rPA)-based enzyme-linked immunosorbent assay (ELISA) was developed to measure the serological response of female A/J mice after inoculation with the new rPA-based anthrax vaccine. Several fundamental parameters of the ELISA were evaluated: specificity, precision, accuracy, linearity, and stability. Experimental results suggested that the quantitative anti-rPA I...

متن کامل

Protection against anthrax by needle-free mucosal immunization with human anthrax vaccine.

Human vaccination with BioThrax requires six injections followed by annual boosters. This makes it difficult for the compliance of the immunization program and underscores the need for development of a new and optimized vaccination protocol. Current research aims to demonstrate the proof of concept to develop a needle-free mucosal immunization protocol using a murine anthrax model. A/J mice wer...

متن کامل

Comparative Assessment of the Whole-cell Pertussis Vaccine Potency Using Serological and Intracerebral Mouse Protection Methods

One of the most important QC tests of whole-cell pertussis vaccine (WCPV) is potency test. In this regard, mouse protection test (MPT) is the current potency method, which is associated with severe animal distress and large variability in results. The purpose of this study was to assess Pertussis Serological Potency Test (PSPT) as a serological alternative method to intracerebral challenge in M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Vaccine

دوره 22 21-22  شماره 

صفحات  -

تاریخ انتشار 2004