Extracranial radiosurgery with volumetric modulated arc therapy: Feasibility evaluation of a phase I trial

نویسندگان

  • FRANCESCO DEODATO
  • SAVINO CILLA
  • GABRIELLA MACCHIA
  • LUCIANA CARAVATTA
  • SAMANTHA MIGNOGNA
  • MARIANGELA MASSACCESI
  • VINCENZO PICARDI
  • CINZIA DIGESU
  • GIUSEPPINA SALLUSTIO
  • PIERLUIGI BONOMO
  • ANGELO PIERMATTEI
  • GABRIELLA FERRANDINA
  • GIOVANNI SCAMBIA
  • VINCENZO VALENTINI
  • NUMA CELLINI
  • ALESSIO G MORGANTI
چکیده

The aim of this study was to report early clinical experience in stereotactic body radiosurgery (SBRS) delivered using volumetric intensity modulated arc therapy (VMAT) in patients with primary or metastatic tumors in various extra-cranial body sites. Each enrolled subject was included in a different phase I study arm, depending on the tumor site and the disease stage (lung, liver, bone, metastatic), and sequentially assigned to a particular dose level. Technical feasibility and dosimetric results were investigated. The acute toxicity, tumor response and early local control were also studied. In total, 25 lesions in 20 consecutive patients (male/female, 11/9; median age, 67 years; age range, 47-86 years) were treated. Of these 25 lesions, 4 were primary or metastatic lung tumors, 6 were liver metastases, 8 were bone metastases and 7 were nodal metastases. The dose-volume constraints for organs at risk (OARs) were observed in 19 patients using a single-arc technique. Only in one patient were two arcs required. The treatment was performed without interruption or any other technical issues. The prescribed dose ranged from 12-26 Gy to the planning target volume (PTV). Delivery time ranged from 4 min to 9 min and 13 sec (median, 6 min and 6 sec). No incidence of grade 2-4 acute toxicity was recorded. The overall response rate was 48% (95% confidence interval (CI), 24.2-70.2) based on computed tomography (CT)/magnetic resonance imaging (MRI) and 89% (95% CI, 58.6-98.7) based on the positron emission tomography (PET) scan. SBRS delivered by means of VMAT allowed the required target coverage to be achieved while remaining within the normal tissue dose-volume constraints in the 20 consecutive patients. VMAT-SBRS resulted in adequate technical feasibility; the maximum tolerable dose has not yet been reached in any study arm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of gated volumetric modulated arc therapy

Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...

متن کامل

Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery

Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery by

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Feasibility of single-isocenter, multi-arc non-coplanar volumetric modulated arc therapy for multiple brain tumors using a linear accelerator with a 160-leaf multileaf collimator: a phantom study

The feasibility of single isocenter, multi-arc non-coplanar volumetric modulated arc therapy (VMAT) for multiple brain tumors was studied using an Elekta Synergy linear accelerator with an Agility multileaf collimator and a Monaco treatment planning system. Two VMAT radiosurgery plans consisting of a full arc and three half arcs were created with a prescribed dose of 20 Gy in a single fraction....

متن کامل

Evaluation of a dedicated brain metastases treatment planning optimization for radiosurgery: a new treatment paradigm?

PURPOSE To investigate the feasibility of a novel dedicated treatment planning solution, to automatically target multiple brain metastases with a single isocenter and multiple inversely-optimized dynamic conformal arcs (DCA), and to benchmark it against the well-established multiple isocenter DCA (MIDCA) and volumetric modulated arc therapy (VMAT) approaches. MATERIAL AND METHODS Ten previous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013