Relationship between electrical and mechanical properties of motor units.
نویسندگان
چکیده
In six healthy volunteers, the size of the motor unit action potential (MUAP) was related to its contractile behaviour. Electrical activity was determined by measuring amplitude and area of the potential, using the macro electromyography (EMG) technique. The mechanical response was characterised by contraction time, twitch force and relaxation time, recorded with the spike triggered averaging technique. With increasing tension of the whole muscle corresponding to an increasing threshold, the force of single units enlarged exponentially compared to their EMG. There was only a weak relationship between contraction time and electrical activity and none between EMG and relaxation time.
منابع مشابه
Novel method for physiological recruitment of diaphragm motor units after upper cervical spinal cord injury.
EACH YEAR, approximately 11,000 people in the United States suffer cervical spinal cord injury that results in partial or complete diaphragm muscle paralysis with an annual expense of more than $3 billion. Those unable to maintain adequate ventilation due to diaphragm muscle paralysis become dependent on mechanical ventilators, a situation associated with ongoing problems related to pulmonary c...
متن کاملThe effect of fast and slow motor unit activation on whole-muscle mechanical performance: the size principle may not pose a mechanical paradox.
The output of skeletal muscle can be varied by selectively recruiting different motor units. However, our knowledge of muscle function is largely derived from muscle in which all motor units are activated. This discrepancy may limit our understanding of in vivo muscle function. Hence, this study aimed to characterize the mechanical properties of muscle with different motor unit activation. We d...
متن کاملEffect of Carbon Nanotube and Surfactant on Processing, Mechanical, Electrical and EMI-Shielding of Epoxy Composites
Dispersing nanoparticles in a polymer matrix is intrinsically challenging due to unfavorable entropic interactions between the matrix and the nanoparticle. In this research dispersion of nanoparticles in polymer matrix was studied and the effect of dispersion on properties was investigated. The properties of polymer composite depend on the type, size, shape, concentration of nanoparticles, and ...
متن کاملTwitch and tetanic properties of human thenar motor units paralyzed by chronic spinal cord injury.
Little is known about how human motor units respond to chronic paralysis. Our aim was to record surface electromyographic (EMG) signals, twitch forces, and tetanic forces from paralyzed motor units in the thenar muscles of individuals (n = 12) with chronic (1.5-19 yr) cervical spinal cord injury (SCI). Each motor unit was activated by intraneural stimulation of its motor axon using single pulse...
متن کاملFiring rates of motor units in human vastus lateralis muscle during fatiguing isometric contractions.
We investigated the firing rate of motor units in the vastus lateralis muscle in five healthy young men (mean = 21.4 yr, SD = 0.9) during a sequence of isometric constant-torque contractions repeated to exhaustion. The contractions were sustained at 20% of the maximal voluntary level, measured at the beginning of the test sequence. Electromyographic (EMG) signals were recorded via quadrifilar f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neurology, neurosurgery, and psychiatry
دوره 53 4 شماره
صفحات -
تاریخ انتشار 1990