Solid state lasers for wide-field CARS microscopy

نویسندگان

  • D. Simanovskii
  • I. Toytman
  • D. Palanker
چکیده

We discuss the requirements for laser systems used in Coherent Anti-Stokes Raman Scattering (CARS) microscopy and particularly in its wide-field modification. While such laser parameters as wavelength, spectral width and frequency difference between pump and Stokes beams are similar for all CARS systems, requirements for pulse energy, repetition rate, pulse length and mode structure might be significantly different for scanning and wide-field approaches. We will present results obtained with a wide-field CARS microscope with non-phase matching illumination and compare its performance with other CARS microscopes. Objectives for the design of future laser systems for CARS microscopy will be outlined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wavelength Selectable Solid-State Raman lasers in the Visible and Ultraviolet Ranges

Solid-state Raman lasers are known as important sources at normally difficult to access wavelengths, and our recent studies have shown that they also form the basis of a class of wavelength selectable lasers. This paper summarizes our recent studies in wavelength selectable Raman lasers in the visible (532-650 nm) and ultraviolet (266-321 nm). 

متن کامل

In situ dissolution analysis using coherent anti-Stokes Raman scattering (CARS) and hyperspectral CARS microscopy.

The solid-state form of an active pharmaceutical ingredient (API) in an oral dosage form plays an important role in determining the dissolution rate of the API. As the solid-state form can change during dissolution, there is a need to monitor the oral dosage form during dissolution testing. Coherent anti-Stokes Raman scattering (CARS) microscopy provides rapid, spectrally selective imaging to m...

متن کامل

Epi-detecting label-free multimodal imaging platform using a compact diode-pumped femtosecond solid-state laser

We have developed an epi-detected multimodal nonlinear optical microscopy platform based on a compact and cost-effective laser source featuring simultaneous acquisition of signals arising from hyperspectral coherent anti-Stokes Raman scattering (CARS), two-photon fluorescence, and second harmonic generation. The laser source is based on an approach using a frequency-doubled distributed Bragg re...

متن کامل

Wide-Field Detected Fourier Transform CARS Microscopy

We present a wide-field imaging implementation of Fourier transform coherent anti-Stokes Raman scattering (wide-field detected FT-CARS) microscopy capable of acquiring high-contrast label-free but chemically specific images over the full vibrational 'fingerprint' region, suitable for a large field of view. Rapid resonant mechanical scanning of the illumination beam coupled with highly sensitive...

متن کامل

Comment on "Wide-field coherent anti-Stokes Raman scattering microscopy with non-phase-matching illumination".

We comment on a Letter by Toytman et al. [Opt. Lett.32, 1941 (2007)] in which a novel setup for wide-field imaging in coherent anti-Stokes Raman scattering (CARS) microscopy is demonstrated. There the authors state that our phase-matching implementation of a wide-field CARS system [Appl. Phys. Lett.84, 816 (2004); New J. Phys.8, 36 (2006)] suffers from a strong background from the bulk medium. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009