Retrospective review of 120 celect inferior vena cava filter retrievals: experience at a single institution.
نویسندگان
چکیده
PURPOSE To evaluate retrospectively the safety and retrievability of the Celect IVC filter. MATERIALS AND METHODS All patients undergoing Celect filter placement and retrieval during the period 2007-2012 were assessed for complications and retrievability. RESULTS Of 620 patients who underwent Celect filter placement, 120 presented for removal. The indwelling time in these patients was 158.1 days±103.0 (range, 2-518 d). There were 106 filters (88.3%) removed; 14 filters were left in situ for the following reasons: filter embedment (n=6), caval occlusion (n=3), retained thrombus (n=2), large floating thrombus in IVC (n=2), or tilt >15° (n=1). With filters in place, five patients developed new pulmonary embolism (PE), and two others presented with severe abdominal pain. The available 115 pairs of placement and removal cavagrams suggested limb penetration in 99 cases (86.1%), intracaval migration >2 cm in 5, secondary tilt >15° in 8, filter deformity in 10, retained thrombus within filters in 12, and IVC occlusion in 3. Among 38 available computed tomography (CT) scans, 9 scans (24%) showed asymptomatic limb penetration to the duodenum (n=6), aortic wall (n=2), or kidney (n=1). No filter fracture was found. CONCLUSIONS This study showed a high penetration rate for Celect IVC filters, including penetrations that were symptomatic or involved adjacent structures. Penetration appears to correlate with indwelling time, suggesting that the filter should be removed as soon as PE protection is no longer indicated. Although most of the filters were removed, 5.8% of retrievals were unsuccessful because of technical failure.
منابع مشابه
Should We Remove the Retrievable Cook Celect Inferior Vena Cava Filter? Eight Years of Experience at a Single Center
Background The inferior vena cava filter (IVCF) is very effective for preventing pulmonary embolism in patients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. Methods A retrospective study was performed of 159 patients who underwent retrievable Cook Celect IVCF implantation between January 2007 and April ...
متن کاملThe Celect Platinum Inferior Vena Cava Filter
T he concept of surgical caval interruption was suggested as early as 1868 by Trousseau, who proposed creating a barrier in the inferior vena cava (IVC) to prevent venous emboli from the legs from reaching the lungs.1 In 1967, nearly 100 years later, the first endovenous filter was implanted.2 Although the basic concept of caval filtration has largely remained the same over the past century, ad...
متن کاملVenous thromboembolism after retrieval of inferior vena cava filters.
PURPOSE To determine the incidence of venous thromboembolism (VTE) after removal of retrievable inferior vena cava (IVC) filters. MATERIALS AND METHODS Retrospective study was conducted of 67 patients who underwent 72 consecutive filter retrievals at a single institution. Data collected included VTE status at the time of filter placement, anticoagulant medications at the time of filter retrie...
متن کاملRetrievable Inferior Vena Cava Filters in Patients with Cancer: Complications and Retrieval Success Rate
Active cancer (ACa) is strongly associated with venous thromboembolism and bleeding. Retrievable inferior vena cava filters (RIVCF) are frequently placed in these patients when anticoagulation cannot be continued. Objectives. To describe the complications and retrieval rate of inferior vena cava filters in patients with ACa. Methods. Retrospective review of 251 consecutive patients with RIVCF i...
متن کاملAdvanced Techniques for Complicated IVC Filter Retrievals: A Clinical Perspective
The development of retrievable inferior vena cava (IVC) filters and the expansion of accepted placement indications have resulted in a significant rise in the number of IVC filter placements. However, retrieval rates remain low, increasing the likelihood of longer dwell times and complicated retrievals. Interest in advanced IVC filter retrieval techniques has grown, but standardized approaches ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of vascular and interventional radiology : JVIR
دوره 23 12 شماره
صفحات -
تاریخ انتشار 2012