Riluzole: validation of stability-indicating HPLC, D1 and DD1 spectrophotometric assays.
نویسندگان
چکیده
A stability-indicating reversed-phase high-performance liquid chromatographic assay procedure has been developed and validated for riluzole in the presence of alkaline and oxidative degradation products. The liquid chromatographic separation was achieved and compared isocratically on C18 Zorbax ODS and Poroshell 120 EC-C18 columns by using a mobile phase containing methanol-water, pH = 3.10 (70:30, v/v), at a flow rate of 1 mL/min and ultraviolet detection at 264 nm. The method was linear over the concentration ranges of 20-200 µg/mL (r = 0.9997) and 10-200 µg/mL (r = 0.9995). The limit of detection and quantitation for the two columns were 2 and 6 µg/mL and 1 and 3 µg/mL, respectively. Moreover, spectrophotometric methods were applied for the determination of riluzole in the presence of its oxidative degradation products by using first derivative spectrophotometry at 252.5 and 275.0 nm. The method was linear over the concentration range of 1-20 µg/mL (r = 0.9995 and 0.9996) at the studied wavelengths, with limits of detection and quantitation of 0.1 and 0.3 µg/mL. In addition, the first derivative ratio spectrophotometry (DD1) method was applied for the determination of riluzole in the presence of its alkaline degradation product at 252.0, 278.5 and 306.3 nm by using 100 µg/mL of alkaline degraded riluzole as a divisor; riluzole was additionally determined in the presence of its hydrogen peroxide oxidative degradation products at 252.5, 275.0 and 305.0 nm by using 200 µg/mL of oxidative degraded riluzole as a divisor. The DD1 method was linear over the concentration range of 1-20 µg/mL (r = 0.9996, 0.9995 and 0.9996 for the alkaline degradation product at the three studied wavelengths, respectively; and r = 0.9995, 0.9996 and 0.9995 for the oxidative degradation product at the three studied wavelengths, respectively), with limits of detection and quantitation of 0.1 and 0.3 µg/mL for both alkaline and oxidative degradation products. The two studied chromatographic and spectrophotometric methods were comparable and display the required accuracy, selectivity, sensitivity and precision to assay riluzole in bulk and pharmaceutical dosage forms. Degradation products resulting from the stress studies did not interfere with the detection of riluzole, which indicates that these are stability-indicating assays.
منابع مشابه
Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملRapid and simple stability indicating HPLC method for the determination of cilazapril in pure substance and pharmaceutical formulation in comparison with classic and derivative spectrophotometric methods.
The present study describes development and subsequent validation of high performance liquid chromatographic method (HPLC) in comparison with spectrophotometric methods (classic, first, second and third order derivative) for determination of pure cilazapril in substance and pharmaceutical preparation. The main aim of this study was to find the method suitable not only for determination of cilaz...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of chromatographic science
دوره 52 6 شماره
صفحات -
تاریخ انتشار 2014