A Technique for Removing Implant-Retained Denture: Direct Relining Complication

نویسندگان

  • İbrahim Duran
  • Betül Yilmaz
  • Çağrı Ural
چکیده

The aim of this case report is to present a technique for removing the denture which locked to ball-attachment because of excessive hard relining resin material flows around the ball-attachment. An alternative method was used in the present case. A cylindrical resin was removed with a diamond bur at the level of matrix and by this way the matrix was removed safely. The advantage of the presented method is that it may be extended to other clinical situations when facing a similar complication for implant supported dentures and also that the technique is simple and does not require special equipment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

PURPOSE The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clin...

متن کامل

Early Loaded Single Implant Reinforced Mandibular Overdenture

Rehabilitating atrophied mandible with two-implant supported denture is a common treatment modality for implant retained removable overdenture in mandible. This paper aims to design a treatment modality where single implant reinforced overdenture is fabricated for a severely atrophied mandibular ridge with early loading protocol. Results of studies have shown that a single implant mandibular ov...

متن کامل

Implant Retained Overdenture Improves the Retention and Stability by Using a Locator System in a Mandibular Edentulous patient: A Case Report

Abstract Complete maxillary and mandibular dentures have been used as a conventional treatment of edentulous patients for longer than a century. Suitable complete maxillary dentures are usually well tolerated but many patients struggle to chew and swallow with the complete mandibular denture because it is too unstable. Previous studies have shown that a mandibular two-implant retained overdentu...

متن کامل

Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review.

OBJECTIVES Research data regarding maxillary complete denture outcome with two-implant supported mandibular overdentures are not consistent. Considering multiple publications on implant supported mandibular overdentures, it was decided to summarize currently present evidence on the maxillary complete dentures opposed by implant-supported mandibular overdentures, and analyze factors that could p...

متن کامل

Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

PURPOSE To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. MATERIALS AND METHODS A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of au...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015