Time Course of Optical Quality and Intraocular Scattering after Refractive Lenticule Extraction

نویسندگان

  • Kazutaka Kamiya
  • Kimiya Shimizu
  • Akihito Igarashi
  • Hidenaga Kobashi
چکیده

PURPOSE To assess the time course of optical quality and intraocular scattering in relation to visual acuity after femtosecond lenticule extraction (FLEx) for the correction of myopia. METHODS This study evaluated 36 eyes of 36 patients with spherical equivalents of -4.38±1.53 D [mean ± standard deviation] who underwent FLEx. Before surgery, and 1 week and 1, 3 and 6 months after surgery, we assessed the modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and OQAS values (OVs), using a double-pass instrument. We also investigated the relationship of the OSI with corrected distance visual acuity (CDVA) preoperatively and postoperatively. RESULTS The mean changes in MTF cutoff frequency, Strehl ratio, OSI, OV100%, OV20%, and OV9% preoperatively and 6 months postoperatively were -5.51 ± 15.01, -0.03 ± 0.07, 0.35 ± 0.83, -0.17 ± 0.48, -0.14 ± 0.38, and -0.09 ± 0.22, respectively. We found no significant preoperative correlation between the OSI and logMAR CDVA (Spearman rank correlation coefficient r = 0.068, p = 0.69), and modest, but significant correlations 1 week and 1, 3, and 6 months postoperatively (r = 0.572, r = 0.562, r = 0.542, r = 0.540, p<0.001, respectively). CONCLUSIONS FLEx induced a transient decrease in optical quality in association with an increase in intraocular scattering in the early postoperative period, possibly due to mild interface haze formation, but gradually recovered with time. It is suggested that this transient degradation in optical quality related to an increase in the intraocular scattering may result in a slight delay of CDVA recovery in the early postoperative period.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Corneal Biomechanical Properties Modification after Small Incision Lenticule Extraction Using Scheimpflug-Based Noncontact Tonometer

PURPOSE To quantify the effect of small incision lenticule extraction (SMILE) on the corneal biomechanics using Scheimpflug noncontact tonometer (Corvis ST). METHODS Twenty eyes of twenty patients, evaluated as eligible for surgery, with high myopia and/or moderate myopic astigmatism, underwent small incision lenticule extraction (SMILE). All patients underwent Corvis ST preoperatively and po...

متن کامل

Visual outcomes after balanced salt solution infiltration during lenticule separation in small-incision lenticule extraction for myopic astigmatism

To evaluate the refractive outcomes of balanced salt solution infiltration during small-incision lenticule extraction (SMILE).This randomized prospective study enrolled 52 patients (104 eyes) with myopic astigmatism. Patients underwent SMILE to correct the myopic astigmatism in Daping Hospital of the Third Military Medical University between January and July 2013. One eye of each patient receiv...

متن کامل

Wound healing profiles of hyperopic-small incision lenticule extraction (SMILE)

Refractive surgical treatment of hyperopia still remains a challenge for refractive surgeons. A new nomogram of small incision lenticule extraction (SMILE) procedure has recently been developed for the treatment of hyperopia. In the present study, we aimed to evaluate the wound healing and inflammatory responses of this new nomogram (hyperopic-SMILE), and compared them to those of hyperopic-las...

متن کامل

Corneal densitometry changes in a patient with interface fluid syndrome after small incision lenticule extraction

BACKGROUND To report a case of interface fluid syndrome (IFS) following small incision lenticule extraction (SMILE) evaluated with corneal densitometry and optical coherence tomography (OCT). CASE PRESENTATION An 18-year-old man reported sudden vision loss 24 days after SMILE procedure. Intraocular pressure (IOP) was 36.3 mmHg (OD) and 36.7 mmHg (OS) by noncontact tonometry. Moderate corneal ...

متن کامل

Quantitative Evaluation of Microdistortions in Bowman's Layer and Corneal Deformation after Small Incision Lenticule Extraction

PURPOSE To quantitatively evaluate microdistortions in Bowman's layer and change in corneal stiffness after small incision lenticule extraction (SMILE). METHODS This was a prospective, longitudinal, and interventional study. Thirty eyes of 30 patients were screened preoperatively and underwent SMILE for treatment of myopia with astigmatism. Visual acuity, refraction, optical coherence tomogra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013