Impact of the use of an endorectal coil for 3 T prostate MRI on image quality and cancer detection rate

نویسندگان

  • Josephin Gawlitza
  • Martin Reiss-Zimmermann
  • Gregor Thörmer
  • Alexander Schaudinn
  • Nicolas Linder
  • Nikita Garnov
  • Lars-Christian Horn
  • Do Hoang Minh
  • Roman Ganzer
  • Jens-Uwe Stolzenburg
  • Thomas Kahn
  • Michael Moche
  • Harald Busse
چکیده

This work aims to assess the impact of an additional endorectal coil on image quality and cancer detection rate within the same patients. At a single academic medical center, this transversal study included 41 men who underwent T2- and diffusion-weighted imaging at 3 T using surface coils only or in combination with an endorectal coil in the same session. Two blinded readers (A and B) randomly evaluated all image data in separate sessions. Image quality with respect to localization and staging was rated on a five-point scale. Lesions were classified according to their prostate imaging reporting and data system (PIRADS) score version 1. Standard of reference was provided by whole-mount step-section analysis. Mean image quality scores averaged over all localization-related items were significantly higher with additional endorectal coil for both readers (p < 0.001), corresponding staging-related items were only higher for reader B (p < 0.001). With an endorectal coil, the rate of correctly detecting cancer per patient was significantly higher for reader B (p < 0.001) but not for reader A (p = 0.219). The numbers of histologically confirmed tumor lesions were rather similar for both settings. The subjectively rated 3-T image quality was improved with an endorectal coil. In terms of diagnostic performance, the use of an additional endorectal coil was not superior.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T2 and Dynamic Contrast Enhanced MR (DCE-MRI) Imaging of Prostate Cancer at 3T

A. M. Gharib, E. Jung, D. Thomasson, S. N. Gupta, G. Metzger, M. Bernardo, Y. McKinney, J. Coleman, C. Menard, P. Choyke Radiology, NIH, Bethesda, MD, United States, NCI, NIH, Bethesda, MD, United States, GE Heathcare, Baltimore, MD, United States, Philips Medical Systems, Bethesda, MD, United States, NCI, Urologic Oncology, NIH, Bethesda, MD, United States, Department of Radiation Oncology, Pr...

متن کامل

Proton and sodium MR imaging of in vivo human prostate using dual-tuned body and endorectal coils at 7T

[Introduction] Prostate cancer is the most frequently diagnosed male malignancy and the second most common cause of cancer death among men in the United States [1]. Prostate cancer typically appears as a low intensity mass against the bright peripheral zone on T2-weighted MR images. Despite its high sensitivity, T2-weighted MR imaging lacks adequate specificity for prostate cancer detection. In...

متن کامل

MR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils

Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...

متن کامل

Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer

PURPOSE Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil ...

متن کامل

MR imaging of the prostate at 3.0T with external phased array coil - preliminary results.

INTRODUCTION Among all imaging modalities, MRI of the prostate has the highest sensitivity to predict extracapsular tumor spread, seems to have added value for the preoperative treatment planning. It is an adjunct tool in patients with high suspicion of prostate cancer and so far negative TRUS-guided biopsies. Due to the higher intrinsic signal, it is expected that 3.0T enables to image the pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017