A Compact Telemanipulated Retinal-Surgery System that Uses Commercially Available Instruments with a Quick-Change Adapter

نویسندگان

  • Manikantan Nambi
  • Paul S. Bernstein
  • Jake J. Abbott
چکیده

We present a telemanipulation system for retinal surgery that uses a full range of unmodified commercially available instruments. The system is compact and light enough that it could reasonably be made head-mounted to passively compensate for head movements. Two mechanisms are presented that enable the system to use commercial actuated instruments, and an instrument adapter enables quick-change of instruments during surgery. A custom stylus for a haptic interface enables intuitive and ergonomic telemanipulation of actuated instruments. Experimental results with a force-sensitive phantom eye show that telemanipulated surgery results in reduced forces on the retina compared to manual surgery, and training with the system results in improved performance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Compact Retinal-Surgery Telemanipulator that Uses Disposable Instruments

We present a retinal-surgery telemanipulation system with submicron precision that is compact enough to be head-mounted and that uses a full range of existing disposable instruments. Two actuation mechanisms are described that enable the use of actuated instruments, and an instrument adapter enables quick-change of instruments. Experiments on a phantom eye show that telemanipulated surgery resu...

متن کامل

Evaluation of haptic in robotic heart surgery

The introduction of telemanipulator systems into cardiac surgery enables the heart surgeon to perform sophisticated mini-invasive and endoscopic procedures with high precision under stereoscopic view. At present, the commercially available robotic surgical systems do not dispose of force feedback for the operating surgeon. The lack of haptic (force or tactile) feedback causes damage of tissue a...

متن کامل

A low‐cost multimodal head‐mounted display system for neuroendoscopic surgery

Background With rapid advances in technology, wearable devices as head-mounted display (HMD) have been adopted for various uses in medical science, ranging from simply aiding in fitness to assisting surgery. We aimed to investigate the feasibility and practicability of a low-cost multimodal HMD system in neuroendoscopic surgery. Methods A multimodal HMD system, mainly consisted of a HMD with ...

متن کامل

Preoperative Sterilization Preparation of the Shoulder: A Comparative Study Evaluating Gauze Sponge and Commercially Available Applicator Prep Stick

Background: Surgical site infection (SSI) remains a concern in shoulder surgery, especially during arthroplasty. Whilemany studies have explored the characteristics and efficacy of different sterilizing solutions, no study has evaluated themethod of application. The purpose of this study was to compare two popular pre-surgical preparatory applications (two4 x 4 cm gauze sponges and applicator s...

متن کامل

Advances in Vitreo-retinal Surgery: 23-gauge Sutureless Pars Plana Vitrectomy

Pars plana vitrectomy is one of the most common surgical procedures performed for the treatment of various vitreo-retinal diseases such as retinal detachment, vitreous haemorrhage, proliferative diabetic retinopathy, epiretinal membrane and macular hole. Traditionally, most vitrectomy surgical systems utilise the 20-gauge instruments pars plana vitrectomy includes multiple incisions including p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016