Mass cytometry: technique for real time single cell multitarget immunoassay based on inductively coupled plasma time-of-flight mass spectrometry.

نویسندگان

  • Dmitry R Bandura
  • Vladimir I Baranov
  • Olga I Ornatsky
  • Alexei Antonov
  • Robert Kinach
  • Xudong Lou
  • Serguei Pavlov
  • Sergey Vorobiev
  • John E Dick
  • Scott D Tanner
چکیده

A novel instrument for real time analysis of individual biological cells or other microparticles is described. The instrument is based on inductively coupled plasma time-of-flight mass spectrometry and comprises a three-aperture plasma-vacuum interface, a dc quadrupole turning optics for decoupling ions from neutral components, an rf quadrupole ion guide discriminating against low-mass dominant plasma ions, a point-to-parallel focusing dc quadrupole doublet, an orthogonal acceleration reflectron analyzer, a discrete dynode fast ion detector, and an 8-bit 1 GHz digitizer. A high spectrum generation frequency of 76.8 kHz provides capability for collecting multiple spectra from each particle-induced transient ion cloud, typically of 200-300 micros duration. It is shown that the transients can be resolved and characterized individually at a peak frequency of 1100 particles per second. Design considerations and optimization data are presented. The figures of merit of the instrument are measured under standard inductively coupled plasma (ICP) operating conditions (<3% cerium oxide ratio). At mass resolution (full width at half-maximum) M/DeltaM > 900 for m/z = 159, the sensitivity with a standard sample introduction system of >1.4 x 10(8) ion counts per second per mg L(-1) of Tb and an abundance sensitivity of (6 x 10(-4))-(1.4 x 10(-3)) (trailing and leading masses, respectively) are shown. The mass range (m/z = 125-215) and abundance sensitivity are sufficient for elemental immunoassay with up to 60 distinct available elemental tags. When <15 elemental tags are used, a higher sensitivity mode at lower resolution (M/DeltaM > 500) can be used, which provides >2.4 x 10(8) cps per mg L(-1) of Tb, at (1.5 x 10(-3))-(5.0 x 10(-3)) abundance sensitivity. The real-time simultaneous detection of multiple isotopes from individual 1.8 microm polystyrene beads labeled with lanthanides is shown. A real time single cell 20 antigen expression assay of model cell lines and leukemia patient samples immuno-labeled with lanthanide-tagged antibodies is presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved ICP-MS measurement: a new method for elemental and multiparametric analysis of single cells.

Time-resolved inductively coupled plasma mass spectrometry (ICP-MS) has attracted much attention for elemental and multiparametric analysis of single cells, instead of a classical bulk analysis of large amount of cells after a dissolution. In the time-resolved measurement, cells are directly introduced into the plasma via nebulizing or micro drop dispensing, and then ion plumes corresponding to...

متن کامل

of the Clustering and Feature Extraction Methods of Mass Cytometry

Introduction Single cell analysis of heterogeneous populations requires the simultaneous quantitative determination of multiple biomarkers for functional and phenotypical identification. However, detailed characterization of single cells has been limited by available probes and instrumentation, where the number of parameters in conventional flow cytometers has been restricted by spectral overla...

متن کامل

Dmd060798 227..233

Advanced single-cell analysis technologies (e.g., mass cytometry) that help in multiplexing cellular measurements in limited-volume primary samples are critical in bridging discovery efforts to successful drug approval. Mass cytometry is the state-of-the-art technology in multiparametric single-cell analysis. Mass cytometers (also known as cytometry by time-of-flight or CyTOF) combine the cellu...

متن کامل

An overview of analytical applications of time of flight-mass spectrometric (TOF-MS) analyzers and an inductively coupled plasma-TOF-MS technique.

A brief overview of the applications of time-of-flight mass spectrometry (TOF-MS) for analytical purposes is presented. The performance of TOF-MS combined with an inductively coupled plasma (ICP) ion source is discussed in detail. The advantages of TOF-MS detectors over the quadrupole mass filters for multi-elemental analysis of fast transient signals are discussed. The applications of ICP-TOF-...

متن کامل

QSRR models of veterinary drugs in milk in ultra-performance liquid chromatography coupled to time of flight mass spectrometry

The veterinary drugs residues are also important pollutants found in milk, since veterinary drugs are commonly used in cattle management. Considering the role of milk in human nutrition and its wide consumption throughout the world, it is very important to ensure the milk quality. A quantitative structure–retention relationship (QSRR) was developed using the partial least square (PLS), Kernel P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 81 16  شماره 

صفحات  -

تاریخ انتشار 2009