Is plating of mid-shaft clavicular fractures possible with a conventional straight 3.5 millimeter locking compression plate?

نویسندگان

  • Wolfgang Grechenig
  • Nima Heidari
  • Ottmal Leitgoeb
  • Walter Prager
  • Wolfgang Pichler
  • Annelie M Weinberg
چکیده

OBJECTIVES Current literature describes improved clinical outcomes and a minor rate of pseudoarthrosis following operatively treated clavicular fractures. We investigated the feasibility of using a standard 3.5 mm AO locking compression plate (LCP) of adequate length for the stabilisation of mid-shaft fractures of the clavicle. METHODS The length and acromial and diaphyseal curvature depths were measured in 49 cadaveric clavicles. We then assessed how well the 6, 7, 8 and 9-hole plates fit on the clavicles. RESULTS The mean clavicular length was 155±12 mm, with a mean acromial curvature of 18.1±3.7 mm and a mean diaphyseal curvature of 12 mm±4 mm. The optimum plate for the clavicle was a 7-hole LCP, providing adequate fixation in 48 of the 49 clavicles. CONCLUSION The described technique for plate osteosynthesis of the clavicle with AO locking compression plate is feasible and results in a biomechanically strong construct for mid-shaft fractures. With the use of a locking plate, comminuted fractures may be bridged without a reduction in the strength of the construct.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

“Comparative Study of Functional Outcome of Dynamic Compression Plating and Interlocking Nailing For Fracture Shaft of Humerus in Adults”

Background: 3% to 5% of all fractures are mid humeral shaft fracture and 2% to 10% are open fractures. The options available for mid shaft fractures are open reduction and internal fixation with plate , and closed reduction and fixation with interlocking nail and conservative. The treatment outcomes have been studied . Objective: In this study we compared the outcome of fracture fixation with d...

متن کامل

Stability of the Proximal Humeral Fracture Treated with Compression, Locking Plating and Inlay Allograft Struts

INTRODUCTION: Stability of the proximal humeral fracture can be difficult to achieved if osteoporosis or severe loss of bone stock is presented. Recently, locking plate technology has included these fractures, but appears that may not be predictable as hoped. Recent studies have demonstrated the importance of both reduction and mechanical support of the medial column in proximal humerus fractur...

متن کامل

Precontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- Years Follow up

Background: The aim of this study was to evaluate functional outcome and complications with a long term followup (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured lockingplates.Methods: We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed,as well as functional evaluation using the rating scale ...

متن کامل

Management of Humeral Shaft Fractures With Intramedullary Interlocking Nail Versus Locking Compression Plate.

Surgical fixation of humeral shaft fractures generally involves plating or nailing. It is unclear whether one method is more effective than the other. The aim of this study was to compare the results of the intramedullary nail and locking compression plate for the treatment of humeral shaft fractures. A total of 60 patients with humeral shaft fractures were randomized to undergo surgery with an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica et traumatologica turcica

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 2011