Quantification of pulmonary regurgitation in patients with repaired Tetralogy of Fallot by 2D phase-contrast MRI: Differences between the standard method of velocity averaging and a pixel-wise analysis

نویسندگان

  • Julio Sotelo
  • Pablo Bächler
  • Jesús Urbina
  • Gerard Crelier
  • Lida Toro
  • Myriam Ferreiro
  • Israel Valverde
  • Marcelo Andia
  • Cristian Tejos
  • Pablo Irarrazaval
  • Sergio Uribe
چکیده

OBJECTIVES To compare the values of pulmonary regurgitation in patients with repaired Tetralogy of Fallot quantified from two-dimensional phase-contrast data, by using a new pixel-wise analysis and the standard velocity-averaging method. DESIGN Quantitative in silico and in vivo analysis. SETTING Hospital Sótero del Río. The magnetic resonance images were acquired using a Philips Achieva 1.5T scanner. PARTICIPANTS Twenty-five patients with repaired Tetralogy of Fallot who underwent cardiovascular magnetic resonance imaging requested by their referring physicians were included in this study. MAIN OUTCOME MEASURES Using a computational fluid dynamics simulation, we validated our pixel-wise method, quantifying the error of our method in comparison with the standard method. The patients underwent a standard two-dimensional phase-contrast magnetic resonance imaging acquisition for quantifying pulmonary artery flow. Pulmonary regurgitation fraction was estimated by using our pixel-wise and the standard method. The two-dimensional flow profiles were inspected looking for simultaneous antegrade and retrograde flows in the same cardiac phase. Statistical analysis was performed with t-test for related samples, Bland-Altman plots, and Pearson correlation coefficient. RESULTS Estimation of pulmonary regurgitation fraction using the pixel-wise analysis revealed higher values compared with the standard method (39 ± 16% vs. 30 ± 22%, p-value <0.01). Eight patients (32%) had a difference of more than 10% between methods. Analysis of two-dimensional flow profiles in these patients revealed simultaneous antegrade and retrograde flows through the pulmonary artery during systole-early diastole. CONCLUSION Quantification of pulmonary regurgitation fraction in patients with repaired Tetralogy of Fallot through a pixel-wise analysis yields higher values of pulmonary regurgitation compared with the standard velocity-averaging method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

بررسی عملکرد بطن‌ها با اکوکاردیوگرافی در نارسایی دریچه ریوی پس از جراحی تترالوژی فالوت

Background: Tetralogy of Fallot is the most common cyanotic congenital heart disease. The systolic and diastolic function in both ventricles is altered even after successful corrective surgery for this defect with a transannular patch. Pulmonary regurgitation, a common complication after this treatment, is usually well tolerated in childhood. The aim of this study was to assess the combined dia...

متن کامل

Enhanced segmentation improves 4D blood flow quantification in patients with tetralogy of Fallot and pulmonary regurgitation

Background 2D phase contrast (PC) MRI provides reliable quantification of blood flow in pts with tetralogy of Fallot (TOF). While 2D PC is the standard for evaluating pulmonary regurgitant fraction, it is limited by single direction velocity measurement and may be inadequate to characterize 3D hemodynamics. Multiple planar acquisitions are often required. While 4D flow MRI provides simultaneous...

متن کامل

Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot. Volumetric quantitation by nuclear magnetic resonance velocity mapping.

BACKGROUND Pulmonary regurgitation frequently occurs after surgical correction of tetralogy of Fallot. To date, reliable quantitation of pulmonary regurgitation has not been possible, and therefore the clinical significance of pulmonary regurgitation is controversial. Nuclear magnetic resonance (NMR) velocity mapping allows accurate measurement of volumetric flow. The feasibility and accuracy o...

متن کامل

Quantifying pulmonary regurgitation and right ventricular function in surgically repaired tetralogy of Fallot: a comparative analysis of echocardiography and magnetic resonance imaging.

BACKGROUND Patients with repaired tetralogy of Fallot are monitored for pulmonary regurgitation (PR) and right ventricular (RV) function. We sought to compare measures of PR and RV function on echocardiogram to those on cardiac magnetic resonance (CMR) and to develop a new tool for assessing PR by echocardiogram. METHODS AND RESULTS Patients with repaired tetralogy of Fallot (n=143; 12.5±3.2 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017