Biomechanical analysis of supracondylar humerus fracture pinning for slightly malreduced fractures.

نویسندگان

  • Tamir Bloom
  • Claire Robertson
  • Andrew T Mahar
  • Peter Newton
چکیده

BACKGROUND The most common position of malreduced type III supracondylar humerus (SCH) fractures is internal rotation and medial collapse of the distal fragment. The purpose of this study was to determine the effect of SCH fracture rotational deformity on stability with various pin configurations. Specifically, is the biomechanical stability lost when an SCH fracture is pinned in slight malreduction (compared with anatomical pinning) improved by adding a third pin? METHODS Sixty-four synthetic humeri were sectioned in the mid-olecranon fossa to simulate an SCH fracture. Specimens were randomized to an anatomically reduced group or a group with 20 degrees of distal fragment internal rotation (n = 32 per group). Each was randomized to one of 4 pin configurations: 2 laterally divergent pins, 2 crossed pins, 3 laterally divergent pins, or 2 lateral with 1 medial pin (n = 8 per group). All fractures were stabilized with 1.6 mm (0.062 in) Kirschner wires. Models were tested in extension, varus, and valgus for 10 cycles between 5 N and 50 N. Internal and external rotations were tested between +/-1 Nm. Data for fragment stiffness (newtons per millimeter or newton millimeters per degree) were analyzed with a 2-way analysis of variance (p < 0.05). RESULTS Internally rotated fractures were significantly less stable than the anatomically reduced group for external rotation, internal rotation, and varus loading regardless of pin configuration. Within the malreduced group, 3-pin configurations were more stable than 2-pin configurations in internal rotation, varus, and extension loading. Two lateral divergent pins were similar to 2 crossed pins, except in extension, where 2 lateral pins had greater stiffness. CONCLUSIONS Construct stiffness for malreduced specimens after pinning was less than those pinned with an anatomical reduction when loaded in varus, internal rotation, and external rotation. For simulated fractures with residual internal rotation, the addition of a third Kirschner wire compared with an anatomically reduced 2-crossed-pin configuration resulted in increased stiffness of the model for all loading directions. CLINICAL RELEVANCE Consider a 3-pin pattern, either 3 laterally divergent pins or 2 lateral pins and 1 medial pin, for SCH fractures when a less than complete anatomical reduction is obtained.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk factors of loss reduction after percutaneous fixation in supracondylar humerus in pediatric: a descriptive-analytical study

Background & Aims: supracondylar humerus fracture is one of the most common pediatric elbow fractures accounting for about 16% of the pediatric fractures. Loss of reduction is one of the complications after closed and percutaneous fixation. This research is aimed to investigate the factors involved in the loss of reduction. Method: In this descriptive study, the children with supracondylar hum...

متن کامل

A Comparative Study of Three Percutaneous Pinning Techniques for Paediatric Supracondylar Humeral Fractures

Supracondylar fracture is one of the most common elbow injuries in children (1). Currently, closed reduction and percutaneous pinning of Gartland's types II and III supracondylar fractures of the humerus in children have become the standard method of treatment (2,3). However, controversy exists about the optimal K-wires configuration required to provide adequate fracture stability to maintain r...

متن کامل

Pediatric Supracondylar Fractures: Are Medial Pins Indicated?

The most common elbow fractures that are seen in children are the supracondylar fractures of the humerus that can be managed by both operative and non-operative modalities [1]. Whether a supracondylar fracture can be managed operatively depends on fracture stability, the degree of displacement and the ability to control displacement through traction [2,3]. Operative management is managed initia...

متن کامل

What is the best fixation technique for the treatment of supracondylar humerus fractures in children?☆

OBJECTIVE To define the best technique for the surgical treatment of supracondylar fracture of the humerus (SFH) in children, evaluating percutaneous pinning with side wires vs. cross-pinning. METHODS Randomized controlled trials using the Medline, CAPES, and BIREME. The criteria for inclusion of articles criteria were: (1) randomized controlled trials (RCTs) comparing percutaneous wire fixat...

متن کامل

Percutaneous pinning in displaced supracondylar fracture of humerus in children.

BACKGROUND Supracondylar fracture of humerus is the most common fracture in first decade of life. There are various treatment modalities for this fracture i.e closed reduction and casting, open reduction and internal fixation and percutaneous pinning. Study was conducted to know the outcome of Percutaneous Pinning in the management of displaced supracondylar fracture of humerus in children. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of pediatric orthopedics

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 2008