Progress on the development of the MediWatch ambulatory blood pressure monitor and related devices.
نویسندگان
چکیده
The MediWatch is a wrist-mounted noninvasive blood pressure monitor designed to capture the radial pulse waveform using arterial tonometry and yield blood pressure measurements when the waveform is calibrated. An early prototype of this monitor uses a pulse-sensing system with a cylindrical plunger to applanate the radial artery. This prototype was evaluated against simulated blood pressure generated by a pneumatic pressure-pulse generator. The simulation-based results show that the prototype gave accurate pressure measurements when the MediWatch waveforms were calibrated against the simulator's pressure, indicating that the pulse-sensing system was able to measure force accurately. The prototype was clinically evaluated against intra-arterial pressure on post-open heart surgery patients. The results show that, under stationary conditions, for short periods of time and when the MediWatch waveforms were calibrated against the intra-arterial pressure, the prototype gave measurements that satisfy some of the statistical criteria of the 1993 Association for the Advancement of Medical Instrumentation standard, the 1993 British Hypertension Society protocol and the 2002 European Society of Hypertension protocol. These clinical results indicate that, under the stated test conditions, the prototype was able to accurately track changes in the patients' systolic and diastolic pressures. The MediWatch is being developed into an ambulatory device that provides a macroscopic view of the patient's blood pressure through measurement at preprogrammed intervals over 24 h, as well as a microscopic view of the patient's pressure through the pulse waveform captured during each measurement cycle. The design features of the MediWatch are being adapted for other applications that require the arterial pulse waveform, calibrated beat-to-beat blood pressure or both. An improved MediWatch prototype has been developed that provides memory storage for measurement data and functions as an integral part of a Web-based system that allows measurement data to be accessed over the Internet. A pulse-wave analyser has been developed that allows the radial pulse waveform to be captured, calibrated and viewed in real time on a personal computer. A continuous noninvasive blood pressure monitoring system based on arterial tonometry is being developed for use as an alternative to the arterial line in invasive blood pressure monitoring.
منابع مشابه
Effects of Ramadan fasting on ambulatory blood pressure in hypertensive patients
Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
متن کاملComparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use.
OBJECTIVE(S) We compared a convenient, cuffless, wrist-type ambulatory blood pressure monitoring (ABPM) device (BPro) and a standard arm-type ABPM monitor under ambulatory conditions. METHODS Fifty normotensive and prehypertensive volunteers who had no interarm differences in BP were enrolled. The wrist and arm monitors were attached to the left wrist and the right arm, respectively, and prov...
متن کاملبررسی تأثیر استفاده از وسایل فردی حفاظت شنوایی در محیط پرسروصدا برروی فشارخون وضربان قلب
Abstract Background: Noise, as the most common industrial hazard, besides hearing loss may have adverse effects on other body systems. Many studies have demonstrated the adverse effects of noise on the cardiovascular system. Using personal protective devices is one of the methods for reducing noise exposure. Controlling noise exposure by means of personal protective devices theoretically reduc...
متن کاملتازه های کاربرد هولتر مونیتورینگ 24 ساعته فشارخون درکودکان
Background : There is always difficulty and inaccuracy in measurement of blood pressure by conventional method in children. Technical errors, human errors, and incompliance of child during measurements are the main disadvantage. Nowadays, 24- hour ambulatory blood pressure measurements (ABPM) are introduced to apply for children. The aim of this review is to update our understanding on the ac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Blood pressure monitoring
دوره 9 3 شماره