Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback.
نویسندگان
چکیده
OBJECT The purpose of this study was to evaluate the accuracy of ventriculostomy catheter placement on a head- and hand-tracked high-resolution and high-performance virtual reality and haptic technology workstation. METHODS Seventy-eight fellows and residents performed simulated ventriculostomy catheter placement on an ImmersiveTouch system. The virtual catheter was placed into a virtual patient's head derived from a computed tomography data set. Participants were allowed one attempt each. The distance from the tip of the catheter to the Monro foramen was measured. RESULTS The mean distance (+/- standard deviation) from the final position of the catheter tip to the Monro foramen was 16.09 mm (+/- 7.85 mm). CONCLUSIONS The accuracy of virtual ventriculostomy catheter placement achieved by participants using the simulator is comparable to the accuracy reported in a recent retrospective evaluation of free-hand ventriculostomy placements in which the mean distance from the catheter tip to the Monro foramen was 16 mm (+/- 9.6 mm).
منابع مشابه
New Technology Virtual Reality in Neurosurgical Education: Part-task Ventriculostomy Simulation
OBJECTIVE: Mastery of the neurosurgical skill set involves many hours of supervised intraoperative training. Convergence of political, economic, and social forces has limited neurosurgical resident operative exposure. There is need to develop realistic neurosurgical simulations that reproduce the operative experience, unrestricted by time and patient safety constraints. Computer-based, virtual ...
متن کاملSecond generation haptic ventriculostomy simulator using the ImmersiveTouch system.
Ventriculostomy is a neurosurgical procedure that consists of the insertion of a catheter into the ventricles of the brain for relieving the intracranial pressure. A distinct "popping" sensation is felt as the catheter enters the ventricles. Early ventriculostomy simulators provided some basic audio/visual feedback to simulate the procedure, displaying a 3D virtual model of a human head. Withou...
متن کاملInvestigation of methods for constructing gloves with tactile and force feedback for virtual reality and telecontrol of anthropomorphic manipulators
Aims. Devices that allow using the functionality of natural hand movements are of the greatest interest. The purpose of this study is to select areas of research at the intersection of several fields of science – biomechanics and cybernetics to develop scientific and technical approaches to track the movements of the operator's fingers and form feedback tactile and force communication received ...
متن کاملVirtual reality-based simulation training for ventriculostomy: an evidence-based approach.
BACKGROUND Virtual reality (VR) simulation-based technologies play an important role in neurosurgical resident training. The Congress of Neurological Surgeons (CNS) Simulation Committee developed a simulation-based curriculum incorporating VR simulators to train residents in the management of common neurosurgical disorders. OBJECTIVE To enhance neurosurgical resident training for ventriculost...
متن کاملLearning retention of thoracic pedicle screw placement using a high-resolution augmented reality simulator with haptic feedback.
BACKGROUND We evaluated the use of a part-task simulator with 3D and haptic feedback as a training tool for a common neurosurgical procedure--placement of thoracic pedicle screws. OBJECTIVE To evaluate the learning retention of thoracic pedicle screw placement on a high-performance augmented reality and haptic technology workstation. METHODS Fifty-one fellows and residents performed thoraci...