Fricke gel dosimeter with improved sensitivity for low‐dose‐level measurements

نویسندگان

  • Mauro Vaiente
  • Wladimir Molina
  • Lila Carrizales Silva
  • Rodolfo Figueroa
  • Francisco Malano
  • Pedro Pérez
  • Mauricio Santibañez
  • José Vedelago
چکیده

Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue-equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, independence of dose rate and incident direction, as well as linear dose response. This work presents the development and characterization of an improved Fricke gel system, based on modified chemical compositions, making possible its application in clinical radiology due to its improved sensitivity. Properties of standard Fricke gel dosimeter for high-dose levels are used as a starting point, and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low-dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose-dependency, showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain an adequate dosimeter response for low-dose levels. A suitable composition from among those studied is selected as a good candidate for low-dose-level radiation dosimetry consisting of a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, Xylenol orange, and tridistilled water. Dosimeter samples are prepared in standard vials for in-phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated using typical X-ray tubes for radiology and calibrated Farmer-type ionization chamber is used as reference to measure dose rates inside phantoms at vial locations. Once sensitive material composition is optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. The aim of this work consists of implementing the optimized gel dosimeter to perform direct measurements of absorbed dose in samples irradiated during microcomputed tomography scanning in order to preliminary assess dose levels for further scanning of small animals for further applications in veterinary and paleontology. As a first attempt, dose distributions were measured in water-equivalent phantoms having dimensions comparable to small animals, 100 to 1000 cm3, approximately. According to the obtained results, it is found that the proposed method shows satisfactory reliability and adequate performance for a promising gel dosimetry system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-sensitivity radiation detector for low dose level radiological applications

Radiation dosimetry by Fricke gel was largely used, generally focused and optimized for radiotherapy applications therefore involving relative high dose levels. Fricke gel dosimetry has several advantages, like dose rate and LET almost independence, 3D mapping, among other. This work presents a novel Fricke gel dosimeter optimized for low dose levels. Several chemical composition were studied v...

متن کامل

Sensitivity and stability of the Fricke–gelatin–xylenol orange gel dosimeter

Spectrophotometric measurements of the Fricke–gelatin–xylenol orange (FGX) gel dosimeter demonstrated reproducible linear dose response up to 25Gy. However, oxidation processes continue post-irradiation, affecting the response of this dosimetry system. Additional oxygenation during preparation increases the sensitivity of the gel but does not improve the auto-oxidation stability of the dosimete...

متن کامل

Fricke Gel Dose Indicators Applicable for Blood Irradiators

Introduction: Transfusion of irradiated blood is recommended by the guidelines for cardiosurgery, cancer surgery, severe trauma and congenital immune deficient recipients. To prevent post- transfusion graft-versus-host disease (PT-GVHD), blood cells may be irradiated by gamma rays. The absorbed dose range for blood irradiation is typically 15 to 50 Gy. As the assurance that blo...

متن کامل

Dosimetry in HDR brachytherapy with Fricke-gel layers and Fricke-gel catheters

Fricke-gel layer dosimeters (FGLD) and Fricke gel dosimetric catheters (FGDC) have been designed and tested with the aim of enquiring their suitability for HDR Ir brachytherapy source control and for in-vivo dose verification during treatment. Anisotropy function measurements have been carried out with FGLDs in which a thin plastic tube has been placed in for the Ir source insertion. FGDCs are ...

متن کامل

Review of Fricke gel dosimeters

The innovation of adding a gel matrix to the traditional Fricke dosimeter to stabilize geometric information established the field of gel dosimetry for radiation therapy. A discussion of Fricke gels provides an overview of the issues that determine the dose response of all gel dosimeters in general. In this paper we review some of the features of Fricke systems to illustrate these issues and, i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016