Measuring functional improvement after total knee arthroplasty requires both performance-based and patient-report assessments: a longitudinal analysis of outcomes.
نویسندگان
چکیده
The purpose was to explore the responsiveness of both patient-report and performance-based outcome measures to determine functional changes during the acute and long-term postoperative recovery after total knee arthroplasty (TKA). One hundred patients scheduled for unilateral TKA underwent testing preoperatively and at 1 and 12 months postoperatively using the Delaware Osteoarthritis Profile. All physical performance measures decreased initially after surgery then increased in the long term; however, the perceived function did not follow the same trend, and some showed an increase immediately after surgery. Patient-report measures were variable, with no to small response early, but had excellent long-term responsiveness that was twice as large as performance measures. Patient perception fails to capture the acute functional declines after TKA and may overstate the long-term functional improvement with surgery.
منابع مشابه
Patient Satisfaction Following Total Knee Arthroplasty: Comparison of Short-Term Results in Rheumatoid Arthritis and Osteoarthritis
Background: Due to the obvious differences in the natural course of rheumatoid arthritis (RA) and osteoarthritis (OA),different functional outcomes might be expected after Total Knee Arthroplasty (TKA) in these distinct patients. Althoughseveral studies have reported the objective outcome of TKA in RA and OA patients, few studies have compared postoperativepatient-satisfaction levels.Methods: I...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملAseptic Revision Knee Arthroplasty With Total Stabilizer Prostheses Achieves Similar Functional Outcomes to Primary Total Knee Arthroplasty at 2 Years: A Longitudinal Cohort Study.
BACKGROUND Patient function is poorly characterized following revision total knee arthroplasty (TKA), although is generally accepted to be inferior to that following primary procedures. METHODS Fifty-three consecutive aseptic revisions to total stabilizer devices were prospectively evaluated, preoperatively and at 6, 26, 52, and 104 weeks postoperatively, using the Oxford Knee Score (OKS), ra...
متن کاملOutcome of revision in comparison with primary total knee arthroplasty in Iran
Abstract Background: In the recent decade, many primary total knee arthroplasties have been carried out in Iran and the number of revision cases is expected to rise with the aging population. The aim of this study was to report the outcome of revision surgery in the country and make a comparison between the outcome of revision and that of the primary arthroplasty. Methods: Retrospectivel...
متن کاملEarly Regain of Function and Proprioceptive Improvement Following Knee Arthroplasty
Background: Techniques that allow early muscle activation, such as closed kinetic chain (CKC) and open kineticchain (OKC) exercises, may play a beneficial role in the early rehabilitation of the reconstructed knee. However,current rehabilitation regimens have not been shown to reverse post-operative quadriceps activation failureand weakness. To investigate whether patients who use a continuous ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of arthroplasty
دوره 26 5 شماره
صفحات -
تاریخ انتشار 2011