Quality of processed blood for autotransfusion.

نویسنده

  • G Shulman
چکیده

Centrifugal red blood cell washers for intraoperative autotransfusion process shed blood during surgery. In this study, the quality of processed fresh, human bank blood was assessed in a standardized laboratory setting during standard, medium, and high flow processing. Red cell recovery rates and plasma washout efficiencies were compared using three different devices. The accurate parameters measuring effectiveness and product quality were red cell mass (RCM) flow rate and the plasma washout efficiency. Cobe BRAT 2, a system with discontinuous flow (DF) and a cylindrical centrifuge bowl, permitted processing in standard and medium flow of 26 and 35 mL RCM/min, respectively, with washout of residual plasma albumin of 93.2 and 91.2%. The Medtronic Sequestra 1000, a DF system with a conical centrifuge bowl processed blood at 15 and 23 mL RCM/min and eliminated plasma albumin with 98.4 and 96.8% washout during standard and medium flow, respectively, with significant red cell loss occurring during medium flow. The respective speeds of high-flow programs with BRAT 2 and Sequestra 1000 were 15 and 22 mL RCM/min, related to a hematocrit in the holding bag, less than that of the incoming blood from the reservoir. Washout was 58.2 and 58.3%, respectively. Fresenius CATS, a continuous flow (CF) device, produced flow rates of 19, 24, and 43 mL RCM/min and plasma albumin elimination of 97.8, 94.4, and 93.3% in standard, medium, and high-flow, respectively. Holding bag hematocrits with CF exceeded that of DF. Standard, medium, and high-flow programs of CATS may be used without restriction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Autotransfusion management during and after cardiopulmonary bypass alters fibrin degradation and transfusion requirements.

UNLABELLED The coagulation-fibrinolytic profile during cardiopulmonary bypass (CPB) has been widely documented. However, less information is available on the possible persistence of these alterations when autotransfusion is used in management of perioperative blood loss. This study was designed to explore the influence of autotransfusion management on intravascular fibrin degradation and postop...

متن کامل

A modified collection and rapid infusion system for shed whole blood autotransfusion during aortic aneurysm surgery.

We describe our experience in 10 patients (5 males) undergoing resection of a descending thoracic aortic aneurysm or a thoracoabdominal aortic aneurysm in which a modified shed whole blood collection and autotransfusion system was used. This modification allows several options for the processing and autotransfusion of shed blood: use of the cell saving device or the ultrafiltration of collected...

متن کامل

A clinical review of autotransfusion and its role in trauma.

AUTOTRANSFUSION is defined as the collection and reinfusion of a patient's own blood. The first description of autotransfusion dates back to 1818, when Blundell1 used it in London to counter postpartum hemorrhage, with a mortality of 50%. Autotransfusion in the setting of chest trauma was first recorded by Elmendorf2 during battle in 1917 and in civilian life in 1931. The earliest reported Amer...

متن کامل

Effect of partial-filling autotransfusion bowls on the quality of reinfused product.

Intraoperative autotransfusion is used in a variety of surgical procedures with the quantity of blood loss dependent upon numerous factors. These procedures may or may not produce a full autotransfusion bowl. The inadequate removal of contaminants has been correlated to the incomplete filling of bowls, resulting in a condition called "Salvaged Blood Syndrome." The purpose of this study was to a...

متن کامل

In Vitro Evaluation of the Fresenius Kabi CATSmart Autotransfusion System.

Use of autotransfusion systems to collect, wash, and concentrate shed blood during surgical procedures is a widely used method for reducing postoperative anemia and the need for blood transfusions. The aim of this study was to evaluate the CATSmart Continuous Autotransfusion System wash program performance with small (200 or 700 mL) and large volumes (1,000 mL) of shed blood and to determine no...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 2000