Fast plaque burden assessment of the femoral artery using 3D black-blood MRI and automated segmentation.

نویسندگان

  • Bernard Chiu
  • Jie Sun
  • Xihai Zhao
  • Jinnan Wang
  • Niranjan Balu
  • Jiachang Chi
  • Jianrong Xu
  • Chun Yuan
  • William S Kerwin
چکیده

PURPOSE Vessel wall imaging techniques have been introduced to assess the burden of peripheral arterial disease (PAD) in terms of vessel wall thickness, area or volume. Recent advances in a 3D black-blood MRI sequence known as the 3D motion-sensitized driven equilibrium (MSDE) prepared rapid gradient echo sequence (3D MERGE) have allowed the acquisition of vessel wall images with up to 50 cm coverage, facilitating noninvasive and detailed assessment of PAD. This work introduces an algorithm that combines 2D slice-based segmentation and 3D user editing to allow for efficient plaque burden analysis of the femoral artery images acquired using 3D MERGE. METHODS The 2D slice-based segmentation approach is based on propagating segmentation results of contiguous 2D slices. The 3D image volume was then reformatted using the curved planar reformation (CPR) technique. User editing of the segmented contours was performed on the CPR views taken at different angles. The method was evaluated on six femoral artery images. Vessel wall thickness and area obtained before and after editing on the CPR views were assessed by comparison with manual segmentation. Difference between semiautomatically and manually segmented contours were compared with the difference of the corresponding measurements between two repeated manual segmentations. RESULTS The root-mean-square (RMS) errors of the mean wall thickness (t(mean)) and the wall area (WA) of the edited contours were 0.35 mm and 7.1 mm(2), respectively, which are close to the RMS difference between two repeated manual segmentations (RMSE: 0.33 mm in t(mean), 6.6 mm(2) in WA). The time required for the entire semiautomated segmentation process was only 1%-2% of the time required for manual segmentation. CONCLUSIONS The difference between the boundaries generated by the proposed algorithm and the manually segmented boundary is close to the difference between repeated manual segmentations. The proposed method provides accurate plaque burden measurements, while considerably reducing the analysis time compared to manual review.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carotid plaque assessment using fast 3D isotropic resolution black-blood MRI.

Black-blood MRI is a promising tool for carotid atherosclerotic plaque burden assessment and compositional analysis. However, current sequences are limited by large slice thickness. Accuracy of measurement can be improved by moving to isotropic imaging but can be challenging for patient compliance due to long scan times. We present a fast isotropic high spatial resolution (0.7×0.7×0.7 mm3) thre...

متن کامل

Targeted Multi-contrast Vessel Wall Imaging of Bilateral Peripheral Artery Disease

Introduction: Peripheral artery disease (PAD) which affects more than a fifth of people over 70 years is associated with high morbidity [1]. Ankle Brachial Index measurement and MR angiography are not sensitive to detect early atherosclerotic changes in the vessel wall [2]. 2D black-blood MRI is highly reproducible for atherosclerotic plaque measurement in the femoral arteries [2]. However curr...

متن کامل

Three-dimensional T2-weighted MRI of the human femoral arterial vessel wall at 3.0 Tesla.

OBJECTIVES To evaluate the potential use of a novel 3D turbo spin-echo (TSE) T2-weighted (T2w) technique for assessing the vessel wall in the superficial femoral artery at 3.0 T. BACKGROUND Magnetic resonance imaging can be used for the noninvasive assessment of atherosclerotic plaque burden in the peripheral circulation. Although black-blood 2D TSE techniques have been used for femoral arter...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence for carotid plaque hemorrhage imaging at 3.0 T.

An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence (IR FSPGR) on a 3-T scanner for carotid plaque imaging is described. It offers clear blood and fat signal suppression at the carotid artery bifurcation and highlights the regions of carotid plaque affected by hemorrhage at 3 T with high contrast and contrast-to-noise ratio compared with other sequences. It can p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 38 10  شماره 

صفحات  -

تاریخ انتشار 2011