The effect of atypical birefringence patterns on glaucoma detection using scanning laser polarimetry with variable corneal compensation.

نویسندگان

  • Christopher Bowd
  • Felipe A Medeiros
  • Robert N Weinreb
  • Linda M Zangwill
چکیده

PURPOSE The purpose of this study was to investigate the effect of the presence of atypical birefringence patterns, as measured by the typical scan score (TSS), on the diagnostic accuracy of a scanning laser polarimeter (the GDx VCC; Carl Zeiss Meditec, Inc., Dublin, CA) assessed by receiver operating characteristic (ROC) curves for discriminating between glaucoma and healthy eyes. METHODS Two hundred thirty-three glaucomatous eyes (repeatable abnormal visual fields by pattern standard deviation [PSD] and/or glaucoma hemifield test [GHT]) from 153 patients with glaucoma and 104 eyes from 71 healthy participants enrolled in the UCSD Diagnostic Innovations in Glaucoma Study (DIGS) were imaged using the GDx VCC. An ROC regression model was used to evaluate the influence of the covariates TSS; disease severity, defined as standard automated perimetry (SAP) mean deviation [MD]; and age in years on the diagnostic accuracy of the GDx parameters nerve fiber indicator [NFI], TSNIT (temporal, superior, nasal, inferior, temporal) average thickness, superior average thickness, inferior average thickness, and TSNIT standard deviation. Areas under the ROC curve were calculated for specific levels of the covariates according to the results provided by the model. RESULTS TSS and SAP MD significantly affected the diagnostic accuracy of each investigated GDx VCC parameter. Low TSSs, indicating the presence of atypical scans, were associated with decreased accuracy. For NFI, ROC curve areas ranged from 0.749 (when TSS = 20) to 0.904 (when TSS = 100). A similar influence of TSS was found for other parameters. In addition, diagnostic accuracy increased with increasing disease severity. For instance, for NFI, ROC curve areas ranged from 0.853 (when SAP MD = -3) to 0.954 (when SAP MD = -15). CONCLUSIONS The diagnostic accuracy of GDx VCC parameters is affected by disease severity and is adversely affected by the presence of atypical retardation patterns (i.e., decreasing TSS). GDx VCC scans with atypical scan patterns should be interpreted with caution when used in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation.

PURPOSE To compare the diagnostic accuracy of scanning laser polarimetry (SLP) parameters between images taken with enhanced corneal compensation (ECC) and those with variable corneal compensation (VCC) and to explore the effect of atypical birefringence patterns on this accuracy. DESIGN Cross-sectional observational study. PARTICIPANTS Forty-one healthy subjects and 92 patients with primar...

متن کامل

Detection of glaucoma using scanning laser polarimetry with enhanced corneal compensation.

PURPOSE To evaluate and compare the diagnostic accuracies for glaucoma detection of scanning laser polarimetry (SLP) with enhanced corneal compensation (GDx ECC) and variable corneal compensation (GDx VCC; both by Carl Zeiss Meditec, Dublin, CA), according to different levels of disease severity and presence of atypical retardation patterns. METHODS The study included 102 eyes of 68 patients ...

متن کامل

Longitudinal measurement variability of corneal birefringence and retinal nerve fiber layer thickness in scanning laser polarimetry with variable corneal compensation.

OBJECTIVE To investigate the longitudinal corneal birefringence (corneal polarization axis [CPA] and corneal polarization magnitude [CPM]) variability in scanning laser polarimetry with variable corneal compensation and its effect on retinal nerve fiber layer measurements. Method We analyzed scanning laser polarimetry images obtained every 6 months for 3.2 years in 16 healthy eyes, 38 eyes with...

متن کامل

Structure-function relationship is stronger with enhanced corneal compensation than with variable corneal compensation in scanning laser polarimetry.

PURPOSE To compare the structure-function relationship between peripapillary retinal nerve fiber layer (RNFL) retardation, measured with scanning laser polarimetry (SLP) with both enhanced and variable corneal compensation (ECC [enhanced corneal compensation] and VCC [variable corneal compensation], respectively; features of the GDx Nerve Fiber Analyzer; Carl Zeiss Meditec, Inc., Dublin, CA), a...

متن کامل

Association between scanning laser polarimetry measurements using variable corneal polarization compensation and visual field sensitivity in glaucomatous eyes.

OBJECTIVE To compare the association between scanning laser polarimetry (SLP) retinal nerve fiber layer (RNFL) measurements and automated perimetry sensitivity using both SLP manufacturer-assumed fixed and subject-specific variable corneal polarization magnitude and corneal polarization axis values. METHODS An SLP was modified to enable the measurement of corneal polarization magnitude and co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 2007