Standard Reference Material 1751: Gallium Melting-Point Standard

نویسنده

  • Gregory F. Strouse
چکیده

The melting point of gallium (29.7646 °C) is a defining thermometric fixed point of the International Temperature Scale of 1990 (ITS-90). Realization of this melting point is performed using a fixedpoint cell containing high-purity (≥99.999 99 wt. % pure) gallium. A 30 kg single lot of gallium (99.999 9956 wt. % pure) constituting Standard Reference Material (SRM) 1751 was evaluated, and certified as suitable for use in the realization of the melting-point temperature of gallium for the ITS-90. Based on results obtained with three fixed-point cells containing random samples of SRM 1751, the expanded uncertainty (k=2) assigned to the melting-point temperature of the metal is 0.07 mK. In this document, the methods used for the fabrication of the gallium melting-point cells and for the evaluation of SRM 1751 are described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The succinonitrile triple-point standard: a fixed point to improve the accuracy of temperature measurements in the clinical laboratory.

In an investigation of the melting and freezing behavior of succinonitrile, the triple-point temperature was determined to be 58.0805 degrees C, with an estimated uncertainty of +/- 0.0015 degrees C relative to the International Practical Temperature Scale of 1968 (IPTS-68). The triple-point temperature of this material is evaluated as a temperature-fixed point, and some clinical laboratory app...

متن کامل

Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein an...

متن کامل

Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC

The determination of chemical purity, melting range, and variation of enthalpy in the process of characterizing medicines is one of the principal requirements evaluated in quality control of the pharmaceutical industry. In this study, the method of purity determination using DSC was outlined, as well as the application of this technique for the evaluation of commercial samples of zidovudine (AZ...

متن کامل

International Council for Standardization in Haematology technical report 1-2009: new reference material for haemiglobincyanide for use in standardization of blood haemoglobin measurements.

The International Council for Standardization in Haematology (ICSH) in conjunction with Eurotrol, B.V. has released a new lot of the haemiglobincyanide or haemoglobin standard. This technical report describes the purpose, methodology in manufacturing, summary of value assignment data and availability of this standard material used for the standardization and calibration of whole blood haemoglob...

متن کامل

The Nist Industrial Thermometer Calibration Laboratory

The NIST Industrial Thermometer Calibration (ITC) Laboratory provides calibrations of industrial thermometers over the range from –196 °C to 550 °C. The different types of thermometers include liquid-in-glass (LiG), thermistors, thermocouples (<200 °C), and industrial platinum resistance thermometers (IPRTs). Calibrations are performed by both comparison with a standard platinum resistance ther...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004